34 Planning and Installation Guidelines
Planning and
Installation Guidelines
Technical Description
Wireless Proximity Switches / Issue: 09.2004
V 6
Display of the field bus parameters for the configuration of the input module
The field bus parameters contain in the first parameter set the Cell-ID - range identification
of the input module (CELL ID). The further eight (CFG 01... CFG 08) show for 16 sensor
numbers each, whether these are configured or not.
The display can change between hexadecimal, binary and decimal representation. In the binary
representation 16 sensors each, from right to the left ascending, are indicated as ”1” for
configured” and as “0” for “not configured”.
If the input module is connected via a field bus, which does not permit upload of the field bus
parameters into the machine control, but however in reverse direction, then the field bus
parameters can be manually copied from this display and be entered manually into the control
program (see 3.11.2).
05 CFG 04 DEC
04113
02 CFG 01 BIN
0010010001101110
01 CELL ID HEX
0032
Procedure
Display content *)
Operator
options
SET-MAIN menue
SET
/\
or
\/
Change to another mode except RUN
Change to RUN mode
Change to system settings
/\
or
\/
ESC
OK
FB PARAMETERS
/\
or
\/
ESC
OK
Change to other systen setting in the SET-mode
Change to SET-MAIN menue
Change to display of the field bus parameters
OK, /\
or
\/
/\
or
\/
ESC
OK
Change between nine parameter sets 01 … 09
Leave parameter-display mode
Change between hexadecimal, binary and decimal
representation
OK
/\
or
\/
ESC
OK
Change between nine parameter sets 01 … 09
Leave parameter-display mode
Change between hexadecimal, binary and decimal
representation
OK, /\
or
\/
/\
or
\/
ESC
OK
Change between nine parameter sets 01 … 09
Leave parameter-display mode
Change between hexadecimal, binary and decimal
representation
OK, /\
or
\/
Description
*) All sensor information and cell-ID identifications are examples; XXX stands for blinking display