Planning and Installation Guidelines 27
Planning and
Installation Guidelines
Technical Description
Wireless Proximity Switches / Issue: 09.2004
V 6
An input module can automatically seize all configured wireless proximity switches in
its reception range, which carry its Cell-ID.
In this way, when exchanging the input module, a very fast recognition of all the wireless proximity
switches installed in a machine by the new input module is possible, and can be stored as valid
configuration.
CFG
AUTO 017 12
CFG
AUTO NONE 12
CFG
AUTO STORE 12
Procedure
Description
Display content *)
Operator
options
CFG- AUTO-DETECT menue
CFG
AUTO 12
/\
or
\/
Change to another free sensor number
Change to CFG-MAIN menue
Change to CFG-AUTO-DETECT-SCAN
/\
or
\/
ESC
OK
CFG- AUTO-DETECT-SCAN for the autromatic configuration of an input module. Until at least one sensor has been
configured, NONE is displayed instead of a sensor number
CFG-AUTO-DETECT-STORE
ESC
Change to CFG-AUTO-DETECT menue
OK
OK
/\
or
\/
ESC
Change to another received sensor number or to
CFG-AUTO-DETECT-STORE
Change to CFG-AUTO-DETECT menue
/\
or
\/
ESC
OK
Change to another received sensor number
Change to CFG-AUTO-DETECT menue
Storage of automatically detected sensors as valid
configuration
/\
or
\/
*) All sensor information and cell-ID identifications are examples; XXX stands for blinking display