![ABB TZIDC-200 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/abb/tzidc-200/tzidc-200_operating-instruction_3460595008.webp)
8
TZIDC-200, TZIDC-210, TZIDC-220
DIGITAL POSITIONER | 42/18-85-EN REV. E
… 2 Use in potentially explosive atmospheres
Preconditions for safe operation of the
positioner
DANGER
Risk of explosion due to hot parts
Hot parts inside the device pose an explosion hazard.
• Never open the device immediately after switch-off.
• A waiting time of at least four minutes should be observed
before opening the device.
When using in hazardous areas, observe the following points:
• Observe the specification and special conditions
applicable for the device in accordance with the relevant
valid certificate.
• Manipulation of the device in any form by the user is not
permitted. Only the manufacturer or an explosion
protection specialist may modify the device
• The IP 65 / NEMA 4x IP rating is only achieved if the
splash guard is screwed in place. Operating the unit
without splash guard cap is prohibited.
• The device may only be operated using instrument air
that is free from oil, water and dust. The use of
flammable gas, oxygen, or oxygen-enriched gas is not
permitted.
Cable gland
Limited temperature range of the M20 × 1.5 plastic cable gland
for explosion protection variants.
The permissible ambient temperature range of the cable gland is
−
20 to 80 °C (
−
4 to 176 °F). When using the cable gland, make
sure that the ambient temperature is within this range. The
cable gland must be installed in the housing with a tightening
torque of 3.8 Nm. When installing the connection of the cable
gland and cable, check for tightness to ensure that the required
IP rating is met.
TZIDC-200 – Ex relevant specification
ATEX – ‘Ex d’ type of protection
Ex marking
Marking
II 2 G Ex d IIC T4/T5/T6
Type Examination Test Certificate
DMT 02 ATEX E 029 X
Type
TZIDC-200 Doc. 901132
Device class
II 2 G
Standards EN
60079-0:2012
EN 60079-1:2014
Temperature Data
Device group II 2 G
Temperature class
Ambient temperature Ta
T4
-40 to 85 °C
T5
-40 to 80 °C
T6
-40 to 65 °C
Electrical Data
Voltage
≤
30 V AC/DC
Current
≤
20 mA
Pneumatic data
Supply pressure
Standard version
≤
6 bar
Marine
version
≤
5.5 bar
Содержание TZIDC-200
Страница 59: ...TZIDC 200 TZIDC 210 TZIDC 220 DIGITAL POSITIONER 42 18 85 EN REV E 59 FM installation drawing No 901176...
Страница 61: ...TZIDC 200 TZIDC 210 TZIDC 220 DIGITAL POSITIONER 42 18 85 EN REV E 61...
Страница 63: ...TZIDC 200 TZIDC 210 TZIDC 220 DIGITAL POSITIONER 42 18 85 EN REV E 63 FM installation drawing No 901265...
Страница 65: ...TZIDC 200 TZIDC 210 TZIDC 220 DIGITAL POSITIONER 42 18 85 EN REV E 65 Change from one to two columns...
Страница 67: ...TZIDC 200 TZIDC 210 TZIDC 220 DIGITAL POSITIONER 42 18 85 EN REV E 67 Notes...