Contents
Current reversal and weak end infeed logic for
distance protection (ZCAL) .............................................................. 60
Current reversal logic.................................................................... 60
Weak end infeed logic .................................................................. 61
Completing the test....................................................................... 62
Current reversal and weak end infeed logic for residual
overcurrent protection (EFCA) ......................................................... 63
Testing the current reversal logic.................................................. 63
Testing the weak-end-infeed logic ................................................ 63
Completing the test....................................................................... 65
Definite and inverse time-delayed residual
overcurrent protection (TEF) ............................................................. 66
Checking the operate values of the
current measuring elements
................................................. 66
Event function (EV)............................................................................ 70
Event recorder ................................................................................... 71
Fuse failure supervision (FUSE)........................................................ 72
Checking that the binary inputs and outputs
operate as expected
.............................................................. 72
Measuring the operate value for the
negative sequence function
.................................................. 73
Measuring the operate value for the zero sequence function....... 74
Checking the operation of the du/dt, di/dt based function ............ 75
Completing the test....................................................................... 76
High speed binary output logic (HSBO)............................................. 77
HSBO- trip from communication logic........................................... 77
HSBO- trip from the high-speed function (HS) ............................. 79
HSBO- trip from the distance protection zone 1 function (ZM1) ... 80
Completing the test....................................................................... 81
Instantaneous overcurrent protection (IOC) ...................................... 82
Measuring the operate limit of set values ..................................... 82
Completing the test....................................................................... 83
Monitoring of AC analogue measurements ....................................... 84
Monitoring of DC analogue measurements ....................................... 85
Setting lockout (HMI) ......................................................................... 87
Scheme communication logic for distance protection
functions (ZCOM) ............................................................................ 88
Testing permissive underreach..................................................... 88
Testing permissive overreach....................................................... 89
Testing blocking scheme .............................................................. 89
Checking of unblocking logic ........................................................ 90
Completing the test....................................................................... 90
Scheme communication logic for residual
overcurrent protection (EFC) ........................................................... 91
Testing the directional comparison logic function ......................... 91
Completing the test....................................................................... 92
Setting group selector (GRP)............................................................. 93
Time delayed overcurrent protection (TOC) ...................................... 94
Measuring the operate limit of set values ..................................... 94
Completing the test....................................................................... 95
Trip logic (TR) .................................................................................... 96
3ph operating mode...................................................................... 96
1ph/3ph operating mode............................................................... 96
Содержание REL 505-C1 2.3 Series
Страница 16: ...10 Note signs Chapter 2 Safety information ...
Страница 40: ...34 Checking the binary I O circuits Chapter 6 Checking the external circuitry ...
Страница 110: ...104 Two step time delayed phase overcurrent protection TOC2 Chapter 10 Verifying settings by secondary injection ...
Страница 114: ...108 Testing the interaction of the distance protection Chapter 11 Verifying the internal configuration ...