![ABB ProcessMaster FEM611 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/abb/processmaster-fem611/processmaster-fem611_operating-instruction_4481010.webp)
10
FEM610 |
PROCESSMASTER | OI/FEM610-EN REV. A
5 . . .Installation
. . .Installation conditions
For devices with a wafer-type design, ABB offers an
installation set as an accessory that comprises threaded rods,
nuts, washers and centering sleeves for installation.
Devices with a wafer-type design
G12060
1
2
3
3
Threaded rod
Nut with washer
Centering sleeves
1
2
3
Figure 6 Installation set for wafer-type installation (example)
The device measures the flowrate in both directions. Forward
flow is the factory setting, as shown in Fig. 7.
Flow direction
Figure 7 Flow direction
Electrode axis
The electrode axis should be horizontal if at all possible or no
more than 45° from horizontal.
Mounting position
Note
Prefer vertical installation in hygienic applications.
With horizontal installation assure the sensor is self-
drainable.
Electrode axis
Vertical installation for measuring abrasive fluids, preferably
with flow in upward direction.
In case of horizontal installation, the Meter tube must always be
completely full.
Provide for a slight incline of the connection for degassing.
1
Figure 8 Orientation of the electrode axis
Figure 9 Mounting position
A
B