2000-OSM, F1
10-27
PUT MULTIPLIER EXPONENT Command
Description: Updates
the
multiplier
exponent for a particular method.
Syntax:
PUT_MULTIPLIER_EXP(method%,value%)
Comments:
method%
is the method table (1-8).
value%
is the new multiplier exponent for the specified method.
Example:
0010 PUT_MULTILPIER_EXP(1,4)
The value of 4 is stored in multiplier exponent of analysis method one.
PUT PERCENT OFF TABLE Command
Description:
Writes an array into the %off column of a Time vs Boiling Point Table (Sim
Dis
analyzers
only).
Syntax:
PUT_POFF_TBL(array!,table%)
Comments:
array!
is a previously dimensioned array that is the data source.
table%
is the Sim Dis TvsBP Table (1-8).
Example:
0010 N = LEN_POFF_TBL(1)
0020 DIM POFF!(N)
0030
GET_POFF_TBL(POFF!,1)
0040
PUT_POFF_TBL(POFF!,2)
Variable N gets the number of entries in the TvsBP Table; array POFF! is
dimensioned to have as many elements as entries in table 1. Then the table
is read into the array and the array is written back to table 2.
PUT PRESSURE OF A ZONE Command
Description:
Updates the set point and ramp rate of the specified zone.
Syntax:
PUT_PRESS(zone%,set point!,ramp rate!)
Comments:
zone%
is the zone number (1-5).
set
point!
is the desired set point value.
ramp rate!
is the desired ramp rate value.
Example:
0010 Z1! = GET_PRESS(1)
0020
PUT_PRESS(2,Z1!,0)
Gets the actual pressure of zone 1 and gets 0 ramp rate and inserts them as
the set point and ramp rate values for zone 2.
PUT REPORT TYPE Command
Description:
Updates settings for the teleprinter report parameters, the same parameters
set in the Printer Report Type screen.
Syntax:
PUT_REPORT_TYPE(report_type%)
Comments:
report_type
0 = RAW DATA and NEVER
1 = RAW DATA and ALWAYS
2 = RAW DATA and ON ALARM
4
=
REGULAR
and
NEVER
5 = REGULAR and ALWAYS
6 = REGULAR and ON ALARM
8 = SHORT and NEVER
9 = SHORT and ALWAYS
10 = SHORT and ON ALARM
Example:
0010 PUT_REPORT_TYPE(2)
A raw data report will be printed on the teleprinter at the end of analysis if an
alarm has been set.