Note/Illustration
Action
For the robot signal exchange proxy:
•
K2.X8 - A2.X6
•
(option): K2.X2 - K4.X8, A2.X1
•
K2.X12 - A2.K3.X6, A2.K3.X7
•
K2.X10 - A1.X13
•
K2.X21 - TempSensor
•
K2.X4 - A1.X9
•
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
•
K2.X1 - T2.X2
•
K2.X17 - G2.X1, G1.X2
•
K2.X6, K2.X11 - A1.X2
•
K2.X7, K2.X22 - Harn. LV robot
power
•
K2.X9 & X13 - FlexPendant
For the Ethernet extension switch (op-
tion):
•
K2.X2 - K4.X8, A2.X1
•
K4.X7 - K5.1.X5
•
K4.X6 - A2.X4
For the connected services gateway:
•
K7.X1 - K2.X3
i
•
K7.X2 - A2.X5
Note
The connector K7.X2 is locked; grab the
connector, push it in to release it and
then remove the connector.
For the main computer:
•
K2.X8 - A2.X6
•
K2.X2 - K4.X8, A2.X1
•
K2.X12 - A2.K3.X6, A2.K3.X7
•
K6.X2 - A2.X9
•
A2.X5 - K7.X2
•
A2.X4 - K4.X6/K5.1.X5
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector A2.X4 to/from
K4.X6.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector A2.X4 to/from
K5.1.X5.
Continues on next page
130
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.5 Installing the fieldbus master
Continued
Содержание OmniCore V250XT
Страница 1: ...ROBOTICS Product manual OmniCore V250XT ...
Страница 2: ...Trace back information Workspace 22A version a10 Checked in 2022 03 02 Skribenta version 5 4 005 ...
Страница 34: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 174: ...This page is intentionally left blank ...
Страница 410: ...This page is intentionally left blank ...
Страница 418: ...This page is intentionally left blank ...
Страница 454: ......
Страница 455: ......