Troubleshooting flowchart
Start-up failure
Check LED PS
Green
Not OK
Not lit
Green
Check LED MS
OK
Problem solved
Check LEDs:
PC PWR, PC HDD,
PC STAT
Lit
Not lit
Troubleshoot robot
signal exchange
proxy K2
Troubleshoot main
computer A2
Not lit
Lit
Check drive unit
status LED
Troubleshoot drive
unit T4
Not OK
Check LEDs:
PC, HMI
OK
Troubleshoot robot
signal exchange
proxy K2
Not lit
Check
Module Status LED
on A1
Troubleshoot power
unit A1
Troubleshoot power
unit A1
xx2100001066
Location of LEDs
LEDs on the robot signal exchange proxy:
MS
AS1/GS1 AS2/GS2 ES1 ES2
ESOUT1
ESOUT2
MON AC
PS
PC
HMI
EP
xx2100001067
Continues on next page
358
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
7 Troubleshooting
7.2.2 Start-up failure