Note/Illustration
Action
xx1900001495
Insert the cable ties into the locking
holes.
4
Reconnect:
•
K2.X8 - A2.X6
•
(option): K2.X2 - K4.X8, A2.X1
•
K2.X12 - A2.K3.X6, A2.K3.X7
•
K2.X10 - A1.X13
•
K2.X21 - TempSensor (G2.TEMP)
•
K2.X4 - A1.X9
•
K2.X3 - A2.K3.X1, K7.X1
(option 3032-1): K2.X3 - K5.1.X4
(option 3037-1): K2.X3 - K3.1.X4
•
K2.X1 - A1.X6
•
K2.X17 - G1.X1, G2.X1, G3.X1,
G4.X1, G5.X1
•
- A1.X2
K2.X11 - A1.X2
•
K2.X7, K2.X22 - Harn. LV robot
power (X1)
•
K2.X9 & X13 - FlexPendant (X4)
5
Concluding procedure
Note/Illustration
Action
.
Close the door.
1
Perform the function tests to verify that
the safety features work properly, see
2
206
Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.3 Replacing the robot signal exchange proxy