Removing the wrist
Note
Action
xx2100002805
If used, remove the bracket with the part
of the ball joint housing still fitted.
1
xx2300000015
Remove all attachment screws but leave
one.
2
Guide pin, M12x150: 3HAC13056-2
Fit guide pins to the wrist unit and then re-
move the remaining screw.
3
xx2300000016
Bit holder and hexagon bit SW10
Pull out the wrist a bit and bring out the
cabling from the wrist unit.
CAUTION
Make sure that the cabling does not get
damaged.
4
Bit holder dimension: 5/16" (14x18 mm)
xx2200001808
Continues on next page
Product manual - IRB 6720
275
3HAC085697-001 Revision: C
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the wrist
Continued