6.4.3 Installation locations for the calibration tools
Location of fixed calibration items
This section shows how the robot is equipped with items for installation of
calibration tools for Axis Calibration (fixed calibration pins and/or bushings).
Installed calibration tools are not shown.
A fixed calibration pin and a bushing for the movable calibration tool are located
on each axis as follows.
If there is not enough space on an axis to install a fixed calibration pin, the axis is
equipped with two bushings instead, for installation of two calibration tools when
calibration is carried out. This is shown in the figure.
xx2300000463
Spare parts
When calibration is not being performed, a protective cover and an o-ring should
always be installed on the fixed calibration pin as well as a protective plug, included
a sealing, in the bushing. Replace damaged parts with new.
Note
Article number
Spare part
Replace if damaged or missing.
3HAC053237-002
Protective plug for bushing
Product manual - IRB 930
569
3HAC086009-001 Revision: A