Note
Action
Push the process hub to the outer arm.
3
Removing the cover of the outer arm
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
For robots with protection class
IP30
Remove the screws on the cover of the outer arm
and remove the cover.
2
xx2300000488
Releasing the straps on the bracket
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Cut the straps on the brackets.
Tip
Take photos of the straps before cut them, to have
as a reference when reconnecting.
2
Disconnecting the air hoses, C1 cabling and C2 cabling (if equipped)
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
122
Product manual - IRB 930
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the process hub
Continued