Calibrating axes 1-3
Note
Action
xx2100002598
Slide the calibration tool
3HAC081390-001 onto base plate and
tighten star knob until calibration tool
is fixed.
1
xx2100002599
Remove lower arm, release brake and
move upper arm towards calibration
tool.
2
xx2100002600
Lock the brake when ball joint makes
contact with calibration tool.
3
See
Fine calibration procedure on FlexPendant
Perform a fine calibration of the upper
arm.
4
Remove the calibration tool when
manipulator arm is in zero position.
5
Repeat these steps for all three upper
arms.
6
See
.
Verify the application in the operating
mode manual reduced speed, before
changing mode to automatic and initi-
ating automatic operation.
7
DANGER
Make sure all safety requirements are
met when performing the first test run.
8
Product manual - IRB 365
205
3HAC079185-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
6 Calibration information
6.5 Calibrating axis 1-3
Continued