Replacing telescopic shaft parts
The following procedure describes how to disassemble the entire telescopic shaft.
The individual components are replaced if they are damaged.
Disassemble the telescopic shaft
Note
Action
xx2100000753
Loosen the two attachment screws and remove
the universal joint with mounting clamp.
1
xx2100000754
Remove the attachment screw, and pull off the
telescope bearing housing.
2
xx2100000755
Pull the upper and lower part of the telescopic
arm apart.
3
Loosen the two attachment screws on the tele-
scope bearing housing, and pull the slide bearing
out and replace.
4
Continues on next page