Practical examples 89
AML 630L6A BAFT
Equivalent circuit corresponding to star connection
Permanent loading points:
* Par. 99.16
However, if higher current is needed to use for a short period (defined by the supplier of
the generator), a higher limit can be used. The PLC must supervise the temperatures of
the generator and avoid overheating it.
Running
Par. 99.21
Stator resistance
R
1
(120 °C)
0.42756 ohm
Par. 99.22
Stator reactance
X
1
4.4324 ohm
Par. 99.24
Magnetizing reactance
X
m
177.59 ohm
Starting
Stator resistance
R
1
(60 °C)
0.39143 ohm
Stator reactance
X
1
4.3061 ohm
Ambient condition
Stator resistance
R
1
(50 °C)
0.34346 ohm
Running
Par. 99.25
Rotor resistance
R
2
’
(120 °C)
0.22680 ohm
Par. 99.23
Rotor reactance
X
2
’
5.8101 ohm
Iron loss resistance
R
Fe
5.13 ohm
Starting
Rotor resistance
R
2
’
(60 °C)
0.22678 ohm
Rotor reactance
X
2
’
5.6445 ohm
Ambient condition
Rotor resistance
R
2
’
(50 °C)
0.19899 ohm
U [V]
F [Hz]
N [rpm]
P [kW]
p.f.
S [kVA]
Ir [A]
Ur [V]
Max. time
Max. amb.
12000
60
1320
3150
0.95cap.
3300
1168*
192
Continuous
50 °C
12000
60
1320
3300
1
3300
1063
179
Continuous
50 °C
X
1
X
2
’
R
2
’
/ s
X
m
U
N
/
3
R
Fe
R
1
Содержание ACS800-67
Страница 1: ...ABB wind turbine converters System description and start up guide ACS800 67 wind turbine converters ...
Страница 4: ......
Страница 76: ...76 Start up with medium voltage stator ...
Страница 99: ...Practical examples 99 1 4 4 3 2 5 6 7 ...
Страница 106: ...106 Practical examples Counterclockwise rotation at drive end D end Power cabinet Encoder ...
Страница 118: ...118 Tracing the source of warnings limits and faults ...
Страница 120: ...Contact us www abb com windconverters 3AUA0000095094 Rev B EN 2017 12 31 ...