![background image](http://html1.mh-extra.com/html/abb/acs355-series/acs355-series_quick-start-up-manual_3322119109.webp)
109
PLC libraries for S7-1200
Adding ABB drives to PROFIBUS DP line
1. Launch TIA portal and click
Open the project view
in the
Start
options.
Note
: After installing GSD files, ABB drives are added to the hardware catalog of TIA portal.
2. In the Project tree pane, double-click
Device & networks
.
Figure 116 Devices and network for S7-1200
3. From the hardware catalog pane, drag and drop the required ABB Drive to the PLC.
Figure 117 ABB drive and PLC
4. Double-click Slave_1 to navigate the device view for adding required PPO type.
Figure 118 PPO type for S7-1200