118 Technical data
Derating
The continuous output currents stated above must be derated if any of the following
conditions apply:
•
• ambient temperature e40 °C (+104°F)
• drive is installed higher than 1000 m (3280 ft) above sea level.
Note:
The final derating factor is a multiplication of all applicable derating factors.
Ambient temperature derating
In the temperature range +40…55 °C (+104…131 °F), the rated output current is derated
by 1% for every added 1 °C (1.8 °F) as follows. The output current is calculated by
multiplying the current given in the rating table by the derating factor.
Altitude derating
At altitudes from 1000 to 4000 m (3300 to 13123 ft) above sea level, the derating is 1% for
every 100 m (328 ft). For a more accurate derating, use the DriveSize PC tool.
I
1N
Nominal input current (rms)
I
2N
Nominal output current. 110% overload is allowed for 1 minute every 5 minutes.
I
cont
Continuous rms output currents with no overload capability
I
max
Maximum output current. Available for 10 seconds at start, otherwise as long as allowed by drive
temperature.
U
n
Supply voltage
P
Typical motor power
Note 1:
The ratings apply at an ambient temperature of 40 °C (104 °F).
Note 2:
To achieve the rated motor power given in the table, the rated current of the drive must be higher
than or equal to the rated motor current.
The DriveSize dimensioning tool available from ABB is recommended for selecting the drive, motor and gear
combination.
Drive type
ACQ810-04...
Continuous rms output current
I
cont
(A)
T = 45 °C (+113 °F) T = 50 °C (+122 °F)
T = 55 °C (+131 °F)
-377A-4
368
348
329
-480A-4
475
450
425
-570A-4
551
522
493
-634A-4
618
585
553
-700A-4
675
639
604
-785A-4
767
726
686
-857A-4
831
788
744
00581898
1.00
0.85
+40 °C
+55 °C
+104 °F
+131 °F
Derating factor
Ambient temperature
Содержание ACQ810-04
Страница 1: ...ABB industry specific drives Hardware manual ACQ810 04 drive modules 200 to 500 kW 300 to 700 hp ...
Страница 4: ......
Страница 10: ...10 ...
Страница 22: ...22 Introduction to the manual ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 75: ...Installation 75 Assembly drawing frame G1 ...
Страница 76: ...76 Installation Assembly drawing frame G2 ...
Страница 83: ...Installation 83 3 6a 6b 5 4 8 4 8 6a 6b 7a 7b 7b ...
Страница 84: ...84 Installation Assembly drawing of installing the drive module to the cabinet frame G1 ...
Страница 85: ...Installation 85 Assembly drawing of installing the drive module to the cabinet frame G2 ...
Страница 89: ...Installation 89 3AUA0000038989 TXD transmitter RXD receiver JRIB V2 V1 V7 V6 1 2 APOW 2 JINT 3 JRIB 1 4 4 JGDR ...
Страница 100: ...100 Installation ...
Страница 104: ...104 Installation checklist ...
Страница 106: ...106 Start up ...
Страница 108: ...108 Fault tracing ...
Страница 128: ...128 Technical data ...
Страница 130: ...130 Dimension drawings Frame G1 Drive module dimensions ...
Страница 131: ...Dimension drawings 131 Frame G1 Drive module dimensions with optional cabling panels H381 ...
Страница 132: ...132 Dimension drawings ...
Страница 133: ...Dimension drawings 133 Frame G1 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Страница 134: ...134 Dimension drawings Frame G2 Drive module dimensions ...
Страница 135: ...Dimension drawings 135 Frame G2 Drive module dimensions with optional cabling panels H381 ...
Страница 136: ...136 Dimension drawings ...
Страница 137: ...Dimension drawings 137 Frame G2 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Страница 138: ...138 Dimension drawings Bottom plate ...
Страница 142: ...142 du dt filters ...
Страница 144: ...3AUA0000120538 Rev A EN 2012 06 27 Contact us www abb com drives www abb com drivespartners ...