114 Maintenance
Replacing the drive module
WARNING!
Follow the safety instructions, page
. Ignoring the
instructions can cause physical injury or death, or damage to the
equipment.
Handle the drive module carefully. Make sure that the module does not fall
down when moving it on the floor and during installation and maintenance
work: Open the support legs by pressing each leg a little down and turning
it aside (1, 2). When ever possible secure the module also with chains.
Do not tilt the drive module (A).
It is
heavy
(over 160 kg [350 lb]) and its
center of gravity is high.
The module will overturn from a sideways tilt of
5 degrees. Do not leave the module unattended on a sloping floor.
1. Ensure that the drive is disconnected from the power line and all other precautions
described under
Safety in installation and maintenance
on page
have been taken
into consideration.
2. Remove the left-hand side upper and lower front covers of the drive module by
undoing the fastening screws. M4×8 combi screws, 2 N·m.
3. Disconnect the drive module busbars from the input cabling panel. Combi screw M12,
70 N·m (52 lbf·ft).
4. Disconnect the drive module busbars from the output cabling panel. Combi screw
M12, 70 N·m (52 lbf·ft).
5. Undo the screws that fasten the drive module to the cabinet at the top and behind the
front support legs.
6. Fasten the extraction ramp to the cabinet base with two screws.
7. Disconnect the power supply cable and the fibre optic cables from the external control
unit and coil them on the top of the drive module. If you have an internal control unit
(+P905), detach the control unit from the drive module by undoing the fastening
screws below the optional modules and turn the control unit and the cables aside.
(Alternatively remove the clamp plate, and disconnect the cables from the control
unit.)
1
2
3
A
Содержание ACQ810-04
Страница 1: ...ABB industry specific drives Hardware manual ACQ810 04 drive modules 200 to 500 kW 300 to 700 hp ...
Страница 4: ......
Страница 10: ...10 ...
Страница 22: ...22 Introduction to the manual ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 75: ...Installation 75 Assembly drawing frame G1 ...
Страница 76: ...76 Installation Assembly drawing frame G2 ...
Страница 83: ...Installation 83 3 6a 6b 5 4 8 4 8 6a 6b 7a 7b 7b ...
Страница 84: ...84 Installation Assembly drawing of installing the drive module to the cabinet frame G1 ...
Страница 85: ...Installation 85 Assembly drawing of installing the drive module to the cabinet frame G2 ...
Страница 89: ...Installation 89 3AUA0000038989 TXD transmitter RXD receiver JRIB V2 V1 V7 V6 1 2 APOW 2 JINT 3 JRIB 1 4 4 JGDR ...
Страница 100: ...100 Installation ...
Страница 104: ...104 Installation checklist ...
Страница 106: ...106 Start up ...
Страница 108: ...108 Fault tracing ...
Страница 128: ...128 Technical data ...
Страница 130: ...130 Dimension drawings Frame G1 Drive module dimensions ...
Страница 131: ...Dimension drawings 131 Frame G1 Drive module dimensions with optional cabling panels H381 ...
Страница 132: ...132 Dimension drawings ...
Страница 133: ...Dimension drawings 133 Frame G1 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Страница 134: ...134 Dimension drawings Frame G2 Drive module dimensions ...
Страница 135: ...Dimension drawings 135 Frame G2 Drive module dimensions with optional cabling panels H381 ...
Страница 136: ...136 Dimension drawings ...
Страница 137: ...Dimension drawings 137 Frame G2 Cabling panels H381 installed into a Rittal TS 8 cabinet ...
Страница 138: ...138 Dimension drawings Bottom plate ...
Страница 142: ...142 du dt filters ...
Страница 144: ...3AUA0000120538 Rev A EN 2012 06 27 Contact us www abb com drives www abb com drivespartners ...