Max. 95%
Max. 95%
5 to 95%
Relative humidity
No condensation allowed. Maximum allowed relative humidity is
60% in the presence of corrosive gases.
IEC 60721-3-2: 1997
IEC 60721-3-1: 1997
IEC 60721-3-3: 2002
Contamination levels
(IEC 60721-3-x)
Class 2C2
Class 1C2
Class 3C2
Chemical gases
Class 2S2
Class 1S3 (packing
must support this,
otherwise 1S2)
Class 3S2. No conduct-
ive dust allowed.
Solid particles
-
-
2
Pollution degree
(IEC/EN 60664-1)
60 to 106 kPa
70 to 106 kPa
70 to 106 kPa
Atmospheric pressure
0.6 to 1.05 atmo-
spheres
0.7 to 1.05 atmo-
spheres
0.7 to 1.05 atmo-
spheres
-
-
10...150 Hz
Vibration
Amplitude
±0.075 mm,
10...57.56 Hz
(IEC 60068-2:6)
Constant peak acceler-
ation 10 m/s² (1 gn),
57.56...150 Hz
R3: Displacement, 25 mm peak to peak, 14200
vibratory impacts
-
Vibration (ISTA)
R6, R8 ISTA 3E): Random, overall
Grms level of 0.54
R3 (ISTA 1A): Drop, 6 faces, 3 edges and 1
corner, 460 mm (18.1 in)
Not allowed
Shock/Drop (ISTA)
R6, R8 (ISTA 3E): Shock, incline impact: 1.2
m/s (3.94 ft/s)
Shock, rotational edge drop: 230 mm (9.1 in)
1) For neutral-grounded TN and TT systems and non-corner grounded IT systems.
2) For corner-grounded TN, TT and IT systems.
Markings
These markings are attached to the drive:
CE mark
Product complies with the applicable European Union legislation. For fulfilling
the EMC requirements, see the additional information concerning the drive EMC
compliance (IEC/EN 61800-3).
BTL (BACnet Testing Laboratories) mark
Product has BACnet conformance certificate.
Technical data 205
Содержание ACH580-31
Страница 1: ... ABB INDUSTRIAL DRIVES ACH580 31 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 16: ...16 ...
Страница 30: ...30 ...
Страница 39: ...Operation principle 39 ...
Страница 56: ...56 ...
Страница 90: ...90 ...
Страница 112: ...R3 1 7 N m 112 Electrical installation IEC ...
Страница 113: ...R6 1 7 N m Electrical installation IEC 113 ...
Страница 114: ...R8 1 7 N m 114 Electrical installation IEC ...
Страница 130: ...R3 Max 250 mA 130 Electrical installation North America NEC ...
Страница 131: ...R6 Electrical installation North America NEC 131 ...
Страница 150: ...150 ...
Страница 152: ...152 ...
Страница 166: ... Fan arrow must point up 166 Maintenance ...
Страница 189: ... Package dimensions and weights R6 R3 R8 26 61 11 38 16 65 23 54 25 74 39 06 15 75 45 59 19 76 Technical data 189 ...
Страница 212: ...212 ...
Страница 214: ...R3 IP21 UL Type 1 3AXD50000028643 214 Dimension drawings ...
Страница 215: ...R3 Option B056 IP55 UL Type 12 3AXD50000045321 Dimension drawings 215 ...
Страница 216: ...R6 IP21 UL Type 1 3AXD50000037446 216 Dimension drawings ...
Страница 217: ...R6 Option B056 IP55 UL Type 12 3AXD50000045351 Dimension drawings 217 ...
Страница 218: ...R8 IP21 UL Type 1 3AXD50000147052 218 Dimension drawings ...
Страница 219: ...R8 Option B056 IP55 UL Type 12 3AXD50000147052 Dimension drawings 219 ...
Страница 220: ...220 ...
Страница 242: ...242 ...
Страница 250: ...250 ...
Страница 254: ...254 ...
Страница 261: ...Dimension drawings The dimensions are in millimeters CAIO 01 bipolar analog I O adapter module 261 ...
Страница 262: ...262 ...
Страница 268: ...268 ...
Страница 275: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 275 ...
Страница 276: ...276 ...
Страница 282: ...282 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...