Ascotel® IntelliGate® 150/300 as of I7.9
Operation and Maintenance
189
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
E-505
Hardware:
DRAM defective
Replace basic system
E-530
Hardware:
BBT Integrity Check:
No free replacement
blocks available
Replace basic system
E-531
Hardware:
BBT Integrity Check:
Inconsistent Bad Block
Table
Replace basic system
E-532
Hardware:
BBT Integrity Check:
ECC has detected an
uncorrectable read
error
Replace basic system
E-533
Hardware:
BBT Integrity Check:
Block 0 is faulty; the
Bad Block Table can-
not be used
Replace basic system
E-404
Software:
Version transfer not
possible: The country
and/or sales channel
in the PBX (EIM card)
does not match the
information in the
configuration data in
the Flash
Using AIMS set a dif-
ferent EIM card and /
or distribution chan-
nel.
E-405
Software:
Version transfer not
possible: Software
release unknown.
Load new system
software onto main-
board
E-522
Software:
Incompatible Boot
software
Contact Support. A
different Boot soft-
ware may have to be
loaded.
E-700
Software/Hardware:
General copy error
Load correct system
software onto main-
board or replace basic
system.
E701
Software:
Copy error between
file system and DRAM
Load correct system
software onto main-
board or replace basic
system.
F0
F1
F2
F3
F4
SYS
Error
Category / Descrip-
tion
Remedy
n
n
2
n
n
2 2 n
n
2
n
n
2
n
2
2 2 n
n
2
n
n
2
2
n
2 2 n
n
2
n
n
2
2
2
2 2 n
n
2
n
2
n
n
n
2 2 n
n
2
n
2
n
n
2
2 2 n
n
2
n
2
n
2
n
2 2 n
n
2
n
2
n
2
2
2 2 n
n
2
n
2
2
n
n
2 2 n
n
2
n
2
2
n
2
2 2 n
n
2