MOTOR WILL NOT RUN
POSSIBLE CAUSE
REMEDY
INSTRUCTION
1. Fuse blown, (5,2,1,3,4)
1. Check for correct voltage
Compare supply voltage with
voltage
on motor name plate
.
Check that the wire is sized
correctly.
R
equires
18
Amp
Circuit Breaker
.
2. Limit switch burned out,
(1,2,3,4)
2. Check motor is wired correctly
Compare wiring of motor to
electrical diagram on drawing.
3. Microswitch burned out,
(1,2,3,4)
3. Don’t use extension cords
According to
AS/NZS
: “ The
size of the conductors…should
be such that the voltage drop
would not exceed 3% to the
farthest outlet for power…” Do
not run motor at 115 VAC –
damage to the motor will occur.
4. Motor burned out,
(1,2,3,4,6)
4. Replace with new part
Replace with new part
5. Voltage to motor
incorrect, (2,1,8)
5. Reset circuit breaker/fuse
Reset circuit breaker/fuse
6. Return unit for repair
Return unit for repair
7. See Installation Manual
See Installation Manual
8. Check wall outlet voltage and wiring Make sure unit and wall outlet is
wired properly. Motor must run
at
240
V
single phase
.
26