Checking the Fluid Level
The fluid level can be read through the transparent reservoir at the power unit.
With the
hoist
fully lowered, the fluid level must reach above the min level.
3
.
Grea
sing Points
Slide
Tracks
4
.
Slightly grease the slide tracks over their whole length using a brush.
HOIST STABILITY
1 Every six months check the nuts of all anchor bolts for correct installation torque T
2 Retighten them as required.
Installation Torque
T
AutoLift AL-10000T
80 Nm
The hydraulic fluid must be replaced periodically depending on aging, soiling and water
absorption. It is recommended to replace the pressure hoses as required, but after six
years at the latest.
The slide tracks inside the columns should be greased every six months
(or more frequently in case of noise generation).
24
Содержание AutoLift AL-10000T
Страница 13: ...12 ...
Страница 30: ...曹营 7 Explosion Diagrams and Parts List 7 1 Explosion Diagrams 29 ...
Страница 31: ...气飞 30 ...
Страница 32: ...31 ...
Страница 33: ...4 3 32 ...
Страница 35: ...10 34 ...