FREEZE
GROUP
NAME
SUPERVISED
SCENARIO
52
Freeze
Y
Triggers an alarm when sensor detects low temperatures.
NOTE:
temperature sensor functionality has not been evaluated by UL/
cUL
25
Freeze Non-Reporting
Y
Used for local alerts. Will not report an alarm to the Central Station
*345 MHz temp sensors can be programmed as “Loop” 1 only
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
69
177
Please note:
When using the PG9905 with Group 52, Freeze, the Low threshold setting is set to
40
°F by default. The Low
threshold can be customized between -40°F and
185
°F.
HIGH TEMPERATURE
GROUP
NAME
SUPERVISED
SCENARIO
53
Temp Reporting
Y
Triggers an alarm when sensor detects high temperatures.
NOTE:
temperature sensor functionality has not been evaluated by UL/
cUL
25
Temp Non-Reporting
Y
Used for local alerts. Will not report an alarm to the Central Station
Please note:
When using the PG9905 with Group 53, the High threshold setting is set to 100°F by default. The High
threshold can be customized between -40°F and 185°F.