INSTALLER/DEALER SETTINGS
Setting
Default
Description
EN Grade 2
Disabled
The setting enables EN Grade 2 compliance on the Panel. When Enabled, the following behaviors
and/or settings are changed automatically:
- Entry Procedure (EU) - follows entry procedures and alarm transmission delays specified by EN
50131
- Disables the “Auto Bypass” setting so that the Panel will protest arming when sensor and panel
trouble conditions are present (i.e. Open, Tamper, Low Battery, etc)
- Trouble condition alerts can not be acknowledged until the condition is resolved
- Trouble beeps are expanded to include fault indications required by EN 50131
- “Screen Lock” setting is enabled automatically. Screen will lock 30 seconds after Disarming
- A new icon called “EU Events” is added to the “Settings" page which records mandatory history
events specified by EN 50131.
- “Loss of Supervisory Signals for PowerG Non-Emergency Sensors” is set to 2 hours by default.
- “LED Indicator” setting is Disabled automatically.
- “Partitions” setting is not available.
- “Dealer or Installer Access Requires User Permission” setting is Enabled automatically.
EU Event Swinger Shutdown Count
3
Determines the number of times a particular event will record to “EU Events” log before shutdown.
The count (3-10) will reset after and arm or disarm event.
NOTE:
This setting is greyed out and not
selectable unless EN Grade 2 is Enabled.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
OF
30
177
PROGRAMMING
Содержание Qolsys IQ Panel 2
Страница 8: ...INSTALLING THE PANEL...
Страница 13: ...USER INTERFACE...
Страница 17: ...PROGRAMMING...
Страница 52: ...SECURITY SENSORS...
Страница 84: ...WI FI DEVICES...
Страница 91: ...Z WAVE DEVICES...
Страница 102: ...BLUETOOTH DEVICES...
Страница 110: ...SYSTEM TESTS...
Страница 135: ...CUSTOMIZATION...
Страница 148: ...MAINTENANCE...
Страница 154: ...TROUBLESHOOTING...
Страница 164: ...LEGAL...
Страница 172: ...SPECIFICATIONS...