Specifications
Dimensions
1
Caution:
*Safety valve has been factory fit with the water heater and set at 0.8 MPa
(8 Bar) rated pressure.
Warning:
Do not tamper or detach the safety valve from the water heater.
1
Outlet
2
Inlet
3
Safety Valve*
4
Electronic User interface
5
Decorative Front Panel
6
Front Jacket
7
Back Jacket
8
Anode
9
Heating Element
10
Tank
11
Installation Bracket
12
PU Insulation
13
Thermal Cutout
Part Descriptors
Model
HSE-SCJ
HSE-SCJ
-015
-025
A [mm]
386
444
B1 [mm]
386
444
B2 [mm]
410
478
B3 [mm]
444
513
C [mm]
349
391
12
11
10
9
8
7
13
6
C
4
3
2
1
5
A
B2
B3
B1
Model
HSE-SCJ-015
HSE-SCJ-025
Volume [L]
15
25
Power [W]
3000/2000/1000
3000/2000/1000
Voltage/Frequency [V/Hz]
~230/50
~230/50
Actual Stdg. Loss [kWh/24h/45°C diff.]
0.560
0.690
o
Max. Stdg. Loss [kWh/24h/45 C diff.]
[as per IS 2082:1993 amended in 2002]
1.138
1.386
Reheating Time for 35°C rise [in min]
18
31
Temperature range [°C]
25-75
25-75
2
Rated water pressure
N/cm
80
80
Water head (meters)
80
80
Inlet/Outlet connections [Inch]
½