11
Filling the Water Heater Tank
Operation
1. Op en a nearb y hot w ater faucet to p erm it
air to escap e.
2. Op en the cold w ater inlet valve fully,
filling the w ater heater and the p ip ing .
3. Close hot w ater faucet w hen w ater flow s.
4. Check all the connections to see if there is
any leakag e. In case of a leakag e, d rain
the w ater com p letely, rep air the leaking
joint and then refill the w ater heater.
CAUTION
This w ater heater should not b e op erated w ith insufficient am ount of w ater. Failure to
d o so m ay result in d am ag e to the w ater heater and injuries to the user. This w ill also
m ake the w arranty null and void .
Once the Mounting , Multi-function Safety valve, Plum b ing and Water filling is
com p leted , then only the p ow er sup p ly should b e sw itched ON.
Figure 15
Connecting to Electrical Supply
Figure 16
The p ow er cord and p lug are connected w ith
this w ater heater. Find a sep arate socket for
p ow er p lug and m ake sure the socket is in
firm contact w ith the p lug . Ensure that
reliab le earthing has b een d one.
CAUTION
Connect the w ater heater using ind ep end ent sockets, d o not use any ad ap ters. Use
m ultim eter to check w hether the live line and neutral line are not reverse, to ensure
com p lete safety.
Before installing the w ater heater, confirm that the p ow er of w ater heater m atches electric
m eter cap acity and sup p ly w ire.
The w ater heater should b e earthed reliab ly. It is p rohib ited to connect the earth w ire to
neutral w ire or faucet w ater p ip e.