Configuring the traffic interfaces | 98
10.
Set the DFXS Ringer Output Voltage.
This option sets the DFXS open circuit Ringing Output Voltage which is sourced via an internal
ringing resistance of 178
Ω
per port.
The DC offset on the AC ringing signal enables ring trip to occur with a DC loop either during
ringing cycles. The normal DC line feed voltage enables ring trip to occur with a DC loop in the
silent period between the ringing cycles.
Selection Description
60 Vrms + 0 VDC
Outputs 60 VRMS ringing with no DC offset
Maximum ringing voltage for high ringing load
applications but no DC ring trip
55 Vrms + 10 VDC
Outputs 55 VRMS ringing with a 10 VDC offset
Medium ringing load applications
50 Vrms + 18 VDC
Outputs 50 VRMS ringing with a 18 VDC offset
Above average ringing load applications
45 Vrms + 22 VDC
Outputs 45 VRMS ringing with a 22 VDC offset
Typical application
Default
40 Vrms + 24 VDC
Outputs 40 VRMS ringing with a 24 VDC offset
Lowest terminal power consumption
11.
Select the DFXS Billing Tone Frequency.
This option sets the frequency of billing tone generation. If you are not sure what the expected
frequency of the billing tone should be, check with the exchange equipment supplier.
Selection Description
12 kHz
Use if the CPE requires a 12 kHz billing tone signal
16 kHz
Use if the CPE requires a 16 kHz billing tone signal
Default
Содержание Aprisa XE
Страница 1: ...Aprisa XE User Manual Version 7 3 1 September 2006 ...
Страница 5: ......
Страница 11: ......
Страница 15: ......
Страница 39: ......
Страница 51: ......
Страница 61: ......
Страница 163: ......
Страница 217: ...Interface connections 216 ...
Страница 235: ......
Страница 255: ......
Страница 257: ......
Страница 259: ......
Страница 265: ......
Страница 266: ...Commissioning Forms 265 22 Commissioning Forms ...
Страница 267: ...Commissioning Forms 266 ...
Страница 272: ...Index 271 W web browser cache clearing 180 WEEE 255 ...