3ware Disk Array Configuration Utility
www.3ware.com
65
Auto rebuild on power failure
During driver startup 3ware’s auto rebuild feature sets a flag indi-
cating that the driver loaded. Upon an orderly shutdown the flag is
rewritten, indicating a clean shutdown. During the next system
power cycle the firmware queries the flag. For a RAID 1 or 10 con-
figuration, if there was a problem, the firmware degrades the sec-
ondary drive in the array and starts the background rebuild of the
mirrored drive. When the rebuild is complete the two halves of the
mirror are redundant again. For a RAID 5 configuration, if there is a
problem, the firmware starts the background verification that
checks that the parity matches the data.
Cancelling and restarting a rebuild with a new drive
Currently, a rebuild cannot be cancelled using the 3DM software,
but a rebuild can be aborted by physically removing the disk used to
replace the degraded drive. Abort a rebuild by following the appli-
cable procedure below.
If your system has hot swap carriers
:
1 Remove the disk while the system is powered. The rebuild will
be immediately aborted.
2 Go to the Configure screen and click the box in front of the disk
drive that was removed. Click on Remove Drive.
3 Add another drive and click on the box in front of this port.
Click on Add Drive. The drive is called “RAID Disk”.
4 Click the boxes in front of the RAID Disk and the degraded
array. Select Rebuild. The rebuild starts with the new disk drive.
If your system does not have hot swap carriers
:
1 Power down the system and remove the disk drive that caused
the array to become degraded.
2 Add a different disk drive to rebuild the array.
3 Press Alt + F3 at Boot time to enter 3ware BIOS.
4 Select the degraded array and the newly added drive.
5 Select Rebuild.
Содержание 7000-2 - Escalade RAID Controller
Страница 10: ...3ware Escalade ATA RAID Controller User Guide x...
Страница 32: ...3ware Escalade ATA RAID Controller User Guide 32 www 3ware com...
Страница 99: ......
Страница 116: ...3ware Escalade ATA RAID Controller User Guide 116 www 3ware com Figure 44 Start Device Driver Installation...
Страница 120: ...3ware Escalade ATA RAID Controller User Guide 120 www 3ware com...
Страница 159: ...Checking Array Status www 3ware com 159 Figure 53 3DM Settings Display...
Страница 165: ...Configuration and Array Maintenance Settings www 3ware com 165 Figure 56 3DM Configure Display...
Страница 170: ...3ware Escalade ATA RAID Controller User Guide 170 www 3ware com Figure 57 3DM Help Display...
Страница 188: ...3ware Escalade ATA RAID Controller User Guide 188 www 3ware com...
Страница 194: ...3ware Escalade ATA RAID Controller User Guide 194 www 3ware com...