1
2
3
4
5
6
7
8
9
Appendix B
Appendix B
Appendix B
Appendix B –
–
–
– Error Handling
Error Handling
Error Handling
Error Handling
124
124
124
124
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
User’s Guide
User’s Guide
User’s Guide
User’s Guide
Major
Major
Major
Major Error
Error
Error
Error
Event
Event
Event
Event
Description
Description
Description
Description
Corrective Action
Corrective Action
Corrective Action
Corrective Action
IOP_SPI_BAD_FILE
event.error.
file_handling
Unable to open the
firmware file to be written
to the SPI FLASH.
Perform reader reboot. If condition
persists, contact 3M support.
IOP_SPI_BAD_VERIFY
event.error.
communication
Verification of data in SPI
FLASH failed.
Contact 3M support.
IOP_SPI_INVALID_
FILE_FORMAT
event.error.
file_handling
The firmware file to be
written to the SPI FLASH
does not appear to be in
the proper hex format.
Contact 3M support.
LICENSE_ERROR
event.error.sw
The main processor has
attempted a license
operation or import that
has failed.
Verify license file contains MAC address
of this specific unit. Verify the license
file has not been imported previously. If
condition persists, contact 3M support.
MDM_ADC_DEVICE_
FAILURE
event.error.hw
The ADC device on the
modem has generated an
error.
If condition persists, contact 3M support.
MDM_ANTENNA_
CHECK_FAILURE
event.error.
antenna
The reader cannot perform
an antenna check.
If condition persists, contact 3M support.
MDM_CALIBRATION_
IQ_DATA_CORRUPT
event.error.hw
Invalid transmit offset
calibration data found on
the reader flash.
Contact 3M support.
MDM_CALIBRATION_
IQ_DATA_MISSING
event.error.hw
Unable to find valid
transmit offset calibration
data from the reader flash.
Contact 3M support.
MDM_CALIBRATION_
TX_DATA_CORRUPT
event.error.hw
Invalid transmit power
calibration data found on
the reader flash.
Contact 3M support.
MDM_CALIBRATION_
TX_DATA_MISSING
event.error.hw
Unable to find valid
transmit power calibration
data from the reader flash.
Contact 3M support.
MDM_CNR_CLOSED_
LOOP_FAILED
event.error.radio
CNR closed loop control
failed.
If condition persists, contact 3M support.
MDM_CNR_UPDATE_
WITH_TXOFF
event.error.sw
An error is occurred when
CNR update with
transmission turned off.
If condition persists, contact 3M support.
MDM_FPGA_LOAD_
FAILURE
event.error.hw
Unable to load FPGA device
on the modem.
If condition persists, contact 3M support.
MDM_FPGA_
RAMTEST_FAILURE
event.error.hw
FPGA device on the modem
failed RAM test.
If condition persists, contact 3M support.
MDM_FPGA_RESET_
FAILURE
event.error.hw
FPGA device on the modem
cannot be reset.
If condition persists, contact 3M support.
MDM_FPGA_TIMEOUT
_FAILURE
event.error.hw
PPI bus stopped
unexpectedly
If condition persists, contact 3M support.
MDM_FPGA_TIMEOUT
_WARNING
event.error.hw
Timeout waiting on FPGA
SPI bus.
If condition persists, contact 3M support.