1
2
3
4
5
6
7
8
9
Appendix A
Appendix A
Appendix A
Appendix A –
–
–
– Error Handling
Error Handling
Error Handling
Error Handling
112
112
112
112
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
3M Toll RFID Reader 6204
User’s Guide
User’s Guide
User’s Guide
User’s Guide
com.wiegand.<n>.control.send_test_pattern
Send a fixed, predetermined test pattern to the Wiegand channel.
n = 1 to 4.
Type
Type
Type
Type
function
Permissions
Permissions
Permissions
Permissions
guest=-,admin=x
com.wiegand.<n>.frame.data_index
This variable sets or interrogates the data index. This is the index, in bits,
where serialization of the translated ID begins (for discarding
unused/redundant translated ID bits, for example Dealer Code). n = 1 to 4.
Type
Type
Type
Type
var
Permissions
Permissions
Permissions
Permissions
guest=rw,admin=rw
Data Type
Data Type
Data Type
Data Type
int
Default
Default
Default
Default
24
Min
Min
Min
Min
0
Max
Max
Max
Max
255
com.wiegand.<n>.frame.data_length
This variable sets or interrogates the data length of the Wiegand frame. This
defines the total number of bits (excluding parity bits) of a translated ID that
will be transmitted over the Wiegand interface. n = 1 to 4.
Type
Type
Type
Type
var
Permissions
Permissions
Permissions
Permissions
guest=r,admin=rw
Data Type
Data Type
Data Type
Data Type
int
Default
Default
Default
Default
24
Min
Min
Min
Min
1
Max
Max
Max
Max
112
Содержание 6204