This appendix provides a listing of errors and warnings. Where applicable, a
corrective action has been provided. Errors and warnings are listed by
severity (critical, major, warning) and then alphabetically. If an issue does
not resolve itself after taking the recommended corrective action, contact
3M support.
B.1.
Critical Errors
Critical Errors
Critical Errors
Critical Errors
Critical errors are those errors that are likely to result in loss or severe
degradation of service. These errors must be addressed immediately.
Critical
Critical
Critical
Critical Error
Error
Error
Error
Event
Event
Event
Event
Description
Description
Description
Description
Corrective Action
Corrective Action
Corrective Action
Corrective Action
MDM_ANTENNA_ FAILURE
event.error.
antenna
Failed to set or change
antenna. Probably due to
un-terminated antenna
port.
Check condition of antennas,
connectors, and coax. Use
modem.antennas.perform_check()
to
perform antenna check function to
determine if issue has been located.
MDM_CLOSED_LOOP_
POWER_CTL_FAIL
event.error.
radio
Internal RF power control
failed. May cause
inaccurate antenna power
output.
Perform reader reboot. If condition
persists, contact 3M support.
MDM_OVERTEMP_ FAULT
event.error.
environmental
High temperature
measured at modem
Determine cause of excessive reader
temperature and correct.
MDM_RC_CANT_SET_
FREQUENCY
event.error.
radio
Synthesizer problem tuning
to desired frequency.
Perform reader reboot. If condition
persists, contact 3M support.
MDM_RC_NO_ ANTENNA
event.error.
antenna
Failed to detect antenna.
Probably due to antenna
disconnected.
Check antenna connections, then
perform antenna check function.
MDM_SPI_NO_
RESPONSE
event.error.
communication
Modem has attempted to
communicate with a SPI
bus peripheral and
received no response.
Perform reader reboot. If condition
persists, contact 3M support.
MDM_SYNTHESIZER_
LOCK_FAIL
event.error.
radio
Synthesizer can't lock to
desired frequency.
Perform reader reboot. If condition
persists, contact 3M support.
MDM_TEMPERATURE_
SENSOR_FAIL
event.error.hw
Temperature sensor
unable to detect
temperature.
Perform reader reboot. If condition
persists, contact 3M support.
READER_INIT_FAILURE
event.error.sw
The main processor has
failed to successfully
complete the initialization
process.
Perform reader reboot. If condition
persists, contact 3M support.
SEEPROM_UNABLE_
TO_WRITE
event.error.hw
Unable to write to
SEEPROM.
Perform reader reboot. If condition
persists, contact 3M support.