com.wiegand.<n>.physical.thold
This variable is used to set or to interrogate the inter-frame hold-off time
(Thold), where the inter-frame hold-off time is specified in milliseconds.
Values of 50 to 20,000 ms are valid. The default value is 250 ms. The
variable will return a value in the range 50 to 20,000 ms. n = 1 to 4.
Note that the WIM has a granularity of 50 ms and hold-off times will be
truncated to the nearest 50 ms.
Type
Type
Type
Type
var
Permissions
Permissions
Permissions
Permissions
guest=r,admin=rw
Data Type
Data Type
Data Type
Data Type
int
Default
Default
Default
Default
5
Min
Min
Min
Min
50
Max
Max
Max
Max
20000
com.wiegand.<n>.physical.tpi
This variable is used to set or interrogate the pulse interval time, where the
pulse interval time is specified in microseconds. Values of 200 µs to
20,000 µs are valid. The default value is 2000 µs. The variable will return a
value in the range 200 to 20,000 µs. n = 1 to 4.
Note that the WIM has a granularity of 200 µs. Therefore,
pulse_interval_times will be truncated to the nearest 200 µs.
Type
Type
Type
Type
var
Permissions
Permissions
Permissions
Permissions
guest=r,admin=rw
Data Type
Data Type
Data Type
Data Type
int
Default
Default
Default
Default
2000
Min
Min
Min
Min
200
Max
Max
Max
Max
20000