Signaling — External Links
363
Timer Resolution
All the timers in the Q.2931 and Q.SAAL protocol are based on a
common timer tick-length called the
timer resolution
. When the timer
resolution is changed, all timers are affected.
The CoreBuilder 9000 ATM Enterprise Switch is shipped with a default
timer resolution of 500 msec (.5 secs). To change the value of an
individual timer, you need to change the timer resolution proportionally.
For more information, see “Update Protocol Timer Resolution” on
page 199.
Table 47
Q.2931 Watchdog Timers — Network End
Timer
Name
Default
Time-out
Start Timer
Stop Timer
T303
20
SETUP sent
CONNECT, CALL
PROCEEDING or SETUP
ACK received
T308
150
RELEASE sent
RELEASE COMPLETE or
RELEASE received
T309
50
SAAL abort
SAAL returned to active
state
T310
50
CALL PROCEEDING
received
CONNECT or
DISCONNECT received
T313
20
RELEASE received sent
RELEASE COMPLETE
received
T316
600
PORT RESTART sent
RESTART ACKNOWLEDGE
received
T316c
450
VCC RESTART sent
T317
450
RESTART received
Cancel all call references
T322
20
STATUS ENQUIRY sent
STATUS DISCONNECT,
RELEASE, or RELEASE
COMPLETE received
T398
20
DROP PARTY sent
DROP PARTY
ACKNOWLEDGE or
RELEASE received
T399
70
ADD PARTY sent
ADD PARTY
ACKNOWLEDGE, ADD
PARTY REJECT, or
RELEASE received
TDISC
450
Содержание CoreBuilder 9000
Страница 18: ......
Страница 36: ...36 CHAPTER 1 OVERVIEW...
Страница 44: ......
Страница 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Страница 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Страница 306: ......
Страница 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Страница 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Страница 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Страница 374: ...374 CHAPTER 14 ATM SWITCHING...
Страница 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Страница 426: ......
Страница 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Страница 454: ...454 GLOSSARY...