Signaling Timers
199
Update Protocol
Timer Resolution
Update the timer resolution of the CoreBuilder 9000 ATM Enterprise
Switch. The default timer resolution is 500 msec (0.5 secs); the minimum
timer resolution is 100 msec and there is no upper limit. For more
information, see the previous section and see “Timer Resolution” on
page 363.
This command causes the new timer resolution to be activated in the
current session. The new value is stored in flash.
Command Actions
Command Result
Example
Enter:
1 1 4 1 2 250
The following message appears:
Timer resolution was successfully set.
The timer resolution is updated to 250 msec and saved to flash.
Enter the menu sequence:
(1) SYS: Platform configuration
(1) SET: Switch setup
(4) SIG: Signaling setup
(1) RES: Timer Resolution setup
(2) SET: Set Timer Resolution
Enter a parameter at the prompt
Parameter
Format or Range
Timer Resolution
in millisec; Range: >=100
Direct access sequence:
1 1 4 1 2
[parameters]
System action taken:
The timer resolution is updated.
System message display:
Timer resolution was successfully set.
Содержание CoreBuilder 9000
Страница 18: ......
Страница 36: ...36 CHAPTER 1 OVERVIEW...
Страница 44: ......
Страница 152: ...152 CHAPTER 6 MANAGING NETWORK INTERFACES...
Страница 224: ...224 CHAPTER 8 VIEWING STATISTICS...
Страница 306: ......
Страница 320: ...320 CHAPTER 10 ATM NETWORK BASICS...
Страница 332: ...332 CHAPTER 11 NETWORK INTERFACE MANAGEMENT...
Страница 348: ...348 CHAPTER 12 E IISP PROTOCOL...
Страница 374: ...374 CHAPTER 14 ATM SWITCHING...
Страница 410: ...410 CHAPTER 16 TRAFFIC MANAGEMENT...
Страница 426: ......
Страница 450: ...450 APPENDIX D TECHNICAL SUPPORT...
Страница 454: ...454 GLOSSARY...