Automation Control
=
53
Report Play (vs Still) At End
When the end of the clip is reached, Image Server will report Play to the automation controller,
instead of Still.
Auto E-E
Toggles Auto E-E mode.
Communication Port Parameters
The serial data transfer parameters for the Image Server are fixed, and cannot be changed. These
characteristics are common to all automation controllers:
Baud Rate
38.4 K Baud
Start Bits
1
Data Bits
8
Parity
Odd
Stop Bits
1
Tested Automation Controllers
The Image Server was designed to work with generic VDCP automation controllers; however,
variations do exist between makes and models. The Image Server has been tested by 360 Systems
and found to be compatible with the following controllers. This list is not comprehensive, and the
inclusion or absence of a product does not indicate a preference for any make or model.
Manufacturer
Controller
Protocol
Notes
H
ARRIS
A
UTOMATION
ADC-100
VDCP
ALL HARRIS CONTROLLERS SAME
S
UNDANCE
D
IGITAL
F
AST
B
REAK
VDCP
NV
ERZION
EMC-
NT
VDCP
C
RISPIN
C
ORP
.
S
YSTEM
2000
VDCP
F
LORICAL
A
IR
B
OSS
VDCP
DTG
A
IRO
VDCP
DNF
C
ONTROLS
4000-CL
VDCP
ALSO USED WITH DNF SHOT BOX
DNF C
ONTROLS
300-SSM
P2
BVW-75,
ALSO ODETICS PROTOCOL
A
SH
V
ALE
SM-2
P2
SLOW MOTION CONTROLLER
BUF
VTC-4000
P2
BVW-75,
ALSO ODETICS PROTOCOL
BUF
S
POT
VDCP
ALSO ODETICS PROTOCOL
T
HOMSON
-P
ARKERVISION
PVTV-P
LUS
N
EWS
VDCP
A
LL CR SERIES
L
ANCE
D
ESIGNS
TDC-100
O
DETICS
H
I
-T
ECH
S
YSTEMS
A
CTIV
C
ART
B
OX
VDCP
ALL VDCP PRODUCTS SAME
Содержание V2000 Series
Страница 1: ...O P E R A T I O N S manual I M A G E S E R V E R 2 0 0 0 Model V2000...
Страница 10: ...4 Image Server 2000...
Страница 50: ...44 Image Server 2000...
Страница 56: ...50 Image Server 2000...