25
Installer Programming
Wired Sensor Programming Steps
Q-2
Select wired sensor # (1-2)
Two hardwired loops can be used as sensors with each Control Panel. The
options for each wired sensor are programmed with sub-option questions.
• Begin by entering the wired sensor number or
select it using the
←
or
→
arrows.
• After selecting the wired sensor number, program the wired sensor
details by using the
↑
and
↓
arrows to select each of the sub-options.
✓
NOTE: To skip wired sensor programming, press
SKIP
to jump
from question Q-2 to question Q-3 (RF key fob programming).
Select wired sensor (#) type
DEFAULT: Unused (00)
Each wired sensor needs to be assigned to a sensor type.
• Select the sensor type that matches the wired sensor’s function using the
←
or
→
arrows or enter the sensor type number directly on the keypad.
SENSOR TYPES
(00) unused
(01) exit/entry 1
(02) exit/entry 2
(03) perimeter
(04) interior follower
(05) day zone
(06) 24-hour silent alarm
(07) 24-hour audible alarm
(08) 24-hour auxiliary alarm
(10) interior with delay
(23) no response type
(24) silent burglary
Select wired sensor (#) equipment type
DEFAULT: Varies by wired sensor type
✓
NOTE: This question is only displayed when certain sensor types are selected.
The equipment type selection will affect the sensor’s extended reporting code.
The following sensor types require equipment type selection:
SENSOR TYPE
EQUIPMENT TYPES AVAILA
B
LE
(04) interior follower
(1) = contact (2) = motion
(06) 24-hour silent alarm
(1) = contact (11) = emergency
(07) 24-hour audible alarm
(1) = contact (11) = emergency
(08) 24-hour auxiliary alarm
(1) = contact (6) = freeze (8) = water
(10) = temperature (11) = emergency
(10) interior with delay
(1) = contact (2) = motion
(23) no response type
(1) = contact (2) = motion
• Select the equipment type that matches the sensor equipment using the
←
or
→
arrows, or enter the equipment type number directly on the keypad.
✓
NOTE: This Control Panel does not provide auxiliary accessory output power.
Connecting a hardwire PIR using equipment type “motion” will require
an external stand-alone battery backed-up power supply for the PIR.
Select wired sensor (#) equipment code (0-9999)
DEFAULT: (0)
The wired sensor equipment code defi nes the sensor’s manufacturer and type.
• Enter the 4-digit equipment code for the sensor.
Select wired sensor (#) equipment age (0-1)
DEFAULT: New (0)
The Control Panel can be used with new or existing wired sensors.
• If this wired sensor is new for the installation, leave the default of new (0).
• If this wired sensor is already installed, select existing (1).
Select wired sensor (#) normal state
DEFAULT: Not used (0)
The two hardwired loops can be wired for normally open (N/O) or normally closed
(N/C) contacts, or for end-of-line (EOL) resistor.
• The default (0) disables this wired sensor.
• To use this wired sensor, select the way the loop is wired:
WIRED SENSOR NORMAL STATE
(0) not used
(1) closed
(2) open
(3) end-of-line resistor
Select wired sensor (#) dialer delay (0-1)
DEFAULT: Enabled (1)
(Required SIA CP-01 Default)
Wired sensors can trigger the communicator immediately or after a delay. The
delay time is set by the abort window dialer delay programming question Q-35
(the default delay is 30 seconds).
• The default (1) causes delayed dialing for this wired sensor number.
• For immediate dialing for this wired sensor number, select disabled (0).
✓
NOTE: This default can be changed without affecting SIA CP-01 compliance.
Construct wired sensor (#) voice descriptor
DEFAULT: No default
The voice descriptors are the words the Control Panel will announce for this wired
sensor if this wired sensor is programmed for voice annunciation. Up to fi ve words
are allowed.
• Press
INSERT
to place a word from the vocabulary into the data entry fi eld.
• Use the
←
or
→
arrows to scroll through the words, or enter the
word’s 3-digit index number (see vocabulary table on Page 19).
• Press
INSERT
again for the next word. Up to fi ve words are allowed.
• To move between words, press the
FWD
and
B
ACK
buttons.
• To remove a word, press
DELETE
.
Select wired sensor (#) reports (0-1)
DEFAULT: Enabled (1)
Wired sensors can trigger a report to the Central Station or not.
• The default (1) enables reporting for this wired sensor number.
• To prevent reporting for this wired sensor number, select disabled (0).
Select wired sensor (#) chime (0-5)
DEFAULT: (0) Disabled
Each wired sensor can be set to sound a “ding-dong” chime and/or sound its
voice descriptor when the sensor is triggered.
• The default (0) disables the chime for this wired sensor.
• If a chime and/or voice is required for this wired sensor,
choose one of the other chime options:
WIRED SENSOR CHIME
(0) disabled
(7) ding-ding with voice
(1) voice only
(8) ding-dong #3
(2) ding-dong with voice #1
(9) ding-dong with voice #3
(3) ding-dong #2
(10) chime #1
(4) ding-dong with voice #2
(11) chime #1 with voice #1
(5) ding-dong #1
(12) chime #2
(6) ding-ding
(13) chime #2 with voice #2
Содержание GO!control 2GIG-CNTRL2
Страница 1: ...Wireless Security System Installation Programming Instructions 2GIG CNTRL2 2GIG CP2...
Страница 48: ...46 Notes...
Страница 49: ...47 Notes...
Страница 52: ...v1 9 233497 E Copyright 2012...