Grounding conductor may be required.
Refer to Wiring Section of Manual
*
This water heater is factory equipped for two (2) wire connection to
electrical power. For use with "off-peak" meter (timer) remove wire
nut from red and black leads and connect to "off-peak" meter (timer).
!
SINGLE ELEMENT
DOUBLE ELEMENT
SIMULTANEOUS OPERATION
DOUBLE ELEMENT
SIMULTANEOUS OPERATION
WITH 4 WIRE OUTLET
DOUBLE ELEMENT
NON-SIMULTANEOUS
DOUBLE ELEMENT
NON-SIMULTANEOUS
WITH 4 WIRE OUTLET !
DOUBLE ELEMENT
NON-SIMULTANEOUS
WITH 3 WIRE OUTLET
FIG. A-1
FIG. A-2
FIG. B
FIG. C
FIG. D
FIG. E
FIG. F
2
1
2
THERMOSTAT
& HIGH TEMP.
LIMIT (ECO)
HEATING
ELEMENT
WHITE
BLACK
BLACK
H
JUNCTION
BOX
N
1
G
*
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
120 V ONLY
2
1
2
THERMOSTAT
& HIGH TEMP.
LIMIT (ECO)
HEATING
ELEMENT
RED
BLACK
BLACK
L1
G
*
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
JUNCTION
BOX
4
L2
RED
1
3
SINGLE ELEMENT
2
UPPER
THERMOST
A
T
& HIGH TEMP
.
LIMIT (ECO)
UPPER
HEATING
ELEMENT
BLUE
L1
JUNCTION
BOX
4
L2
1
3
BLACK
RED
BLACK
LOWER
HEATING
ELEMENT
LOWER
THERMOSTAT
& HIGH TEMP
LIMIT (ECO)
1
2
1
1
2
BLUE
CONNECTOR TO "OFF
PEAK"
METER (TIMER)
TM2
4
YELLOW
YELLOW
2
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
BLACK
LOWER
HEATING
ELEMENT
2
UPPER
THERMOSTAT
& HIGH TEMP.
LIMIT (ECO)
UPPER
HEATING
ELEMENT
BLUE
YELLOW
BLACK
L1
JUNCTION
BOX
4
L2
RED
1
3
1
2
BLACK
RED
LOWER
THERMOSTAT
1
2
4
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
2
1
2
UPPER
THERMOSTAT
& HIGH TEMP.
LIMIT (ECO)
UPPER
HEATING
ELEMENT
BLUE
YELLOW
L1
JUNCTION
BOX
4
L2
RED
1
3
1
2
4
BLACK
BLUE
BLACK
BLUE
YELLOW
LOWER
THERMOSTAT
LOWER
HEATING
ELEMENT
TM 1
BLACK
TM 2
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
G
*
G
*
G
*
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION
PANEL
UPPER THERMOST
A
T
& HIGH TEMP
. LIMIT
(ECO)
2
UPPER
HEATING
ELEMENT
BLUE
L1
JUNCTION
BOX
4
L2
1
3
RED (10 GA)
BLACK
LOWER
HEATING
ELEMENT
LOWER
THERMOSTAT
& HIGH TEMP
LIMIT (ECO)
1
2
4
1
3
1
2
RED
2
BLACK (10 GA)
YELLOW
BLACK (10
GA)
RED
(10 GA)
G
*
2
UPPER THERMOST
A
T
& HIGH TEMP
. LIMIT
(ECO)
UPPER
HEATING
ELEMENT
BLUE
L1
BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION PANEL
JUNCTION
BOX
4
L2
1
3
BLACK (10 GA)
RED (10 GA)
BLACK
LOWER
HEATING
ELEMENT
LOWER
THERMOSTAT
& HIGH TEMP
LIMIT (ECO)
1
2
4
1
3
1
2
RED
2
BLUE (10 GA)
TO SECOND POWER SOURCE,
"OFF PEAK" METER, OR
TIMER
TM2
TM1
YELLOW (10 GA)
YELLOW
G
*
THIS ELECTRIC WATER HEATER IS WIRED AS INDICATED ABOVE OR BELOW
Wiring Diagrams
Electric Water Heaters for
3 - Phase Applications
Therm-O-Disc Thermostats
(Type 59T)
For the connection of this
water heat er to a 3-Phase Branch
Circuit, con nect field wiring to
the water heater as indicated in
the ap pro pri ate wiring diagram
at right. A sep a rate junction box
is being supplied with this water
heater (check bot tom of carton)
to accomodate wir ing and con-
duit con nec tions. Install the
Junction Box as shown on the
Installation/Instruction Sheet
in clud ed in the plastic bag
at tached to the heater.
DOUBLE ELEMENT
SIMULTANEOUS OPERATION
DOUBLE ELEMENT
NON-SIMULTANEOUS
FIG. G
FIG. H
2
UPPER
THERMOS
TAT
& HIGH
TEMP
. LIMIT (ECO)
UPPER
HEATING
ELEMENT
BLUE
4
L3
BLA
CK
BLA
CK
LOWER
HEATING
ELEMENT
LOWER
THERMOSTAT
& HIGH TEMP
LIMIT (ECO)
1
1
2
RED
2
BLUE
YELLOW
G
*
YELLO
W
3
L2
1
1
L1
2
4
3- PHASE BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION PANEL
2
UPPER
THERMOST
AT
& HIGH
TEMP
. LIMIT (ECO)
UPPER
HEATING
ELEMENT
BLUE
3- PHASE BRANCH CIRCUIT
TO ELECTRICAL
DISTRIBUTION PANEL
4
L3
BLA
CK (10 GA
)
RED (10 GA)
BLA
CK
LOWER
HEATING
ELEMENT
LOWER
THERMOSTAT
& HIGH TEMP
LIMIT (ECO)
1
4
1
2
RED
2
BLUE (10 GA)
YELLOW
G
*
YELLO
W (10 GA)
3
3
L2
1
1
L1
2
Summary of Contents for Aquaflush Z6000
Page 3: ...P 1A AND P 1B WATER CLOSET ...
Page 17: ...P 2 AND P 2B URINAL ...
Page 31: ...P 3 LAVATORY ...
Page 36: ...P 5 KITCHEN SINK ...
Page 42: ...EWC 1 EWC 2 WATER COOLER ...
Page 56: ...WH 1 WATER HEATER ...
Page 77: ...HWC 1 RECIRC PUMP ...
Page 80: ...SP 1 SUMP PUMP ...