PRIOR TO INSTALLATION:
Important: some options may slightly alter installation. To ensure proper installation review the manual
thoroughly and verify rough-ins before beginning work. File this manual wit the owner or maintenance
personnel upon completion of installation.
—
Fixture mounting requirements: industry standard wall construction, adequate to support the fixture
and installer provided wall anchors sufficient to secure the fixture.
—
Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC
(National Electric Code).
—
Inspect fixture an all parts from damages and all parts are bolted on.
—
To avoid a hazard due to instability of the fixture, it must be fixed in accordance with the instructions.
IMPORTANT:
1. Waste P-Trap, Water Supply Service Angle Stop Valve and 2” x 4” Electrical Plug-In Receptacle to
be supplied by others in accordance with local codes. A metallic p-trap (by others) must be used for
the drain connection.
2. Provide 4” minimum clear space on fixture sides to allow for proper ventilation through cabinet
louvers.
3. Water supply is 3/8” Outer Diameter copper tube. Waste is 1-1/4” Outer Diameter.
4. Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler is
designed to not cause problems with taste, odor, color, or sediment. Optional water filter (Wf1) is
available should any of these problems arise from the water supply.
5. Do NOT solder tubes inserted into the coupler as damage to the o-ring may result.
6. All burrs must be removed from outside of cut tubes before inserting into coupler or other
components.
7. Power supply must be identical in voltage, cycle and phase to that specified on the cooler data
plate. Electrical outlet and furnished power cord with plug must be used to supply power to fixture.
Do NOT wire compressor directly to the power supply.
8. This unit must be grounded per the requirements of applicable electrical codes.
9. Warranty is voided if installation is not made following current Acorn Engineering installation
instructions and if components are assembled to the fixture that is not approved by Acorn
Engineering.
10. Fixture is to operate within a water pressure range of 172kPa (25 psig) to 724kPa (105 psig).
Warranty is void if the unit is allowed to operate outside the range of 172kPa (25 psig) to 724kPa
(105 psig). A pressure regulator must be installed by others on supply line if inlet pressure is
greater than 724kPa (105 psig).
11. Due to cold waste water, Acorn Engineering recommends that p-trap supplied by installer be
insulated to prevent excessive condensation.
12.
All building water supply systems in which quick acting valves are installed shall be provided with
devices to absorb the hammer caused by high pressure resulting from the quick closing of the
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
A171.8
Page 3 of 13
Revised:
12/26/17
7020-904-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
Summary of Contents for Aquaflush Z6000
Page 3: ...P 1A AND P 1B WATER CLOSET ...
Page 17: ...P 2 AND P 2B URINAL ...
Page 31: ...P 3 LAVATORY ...
Page 36: ...P 5 KITCHEN SINK ...
Page 42: ...EWC 1 EWC 2 WATER COOLER ...
Page 56: ...WH 1 WATER HEATER ...
Page 77: ...HWC 1 RECIRC PUMP ...
Page 80: ...SP 1 SUMP PUMP ...