IMPORTANT
This Fixture is intended for indoor use only and is not suitable for installation in an area where a water jet
could be used as well as in environments where freezing may occur. This fixture dispenses water that has
been lowered in temperature, but otherwise remains unchanged by the materials in the water cooler . It is
common for electrical equipment to be grounded to water lines either within a structure or away from it.
Every attempt should be made to prevent this kind of grounding from generating electrical feedback into the
water cooler creating electrolysis. Electrolysis will cause a metallic taste or cause water metal content to
increase.
NOTICE
A dielectric coupling must be used to connect the water cooler to the water supply . A nonmetallic coupler is
furnished with this water cooler to meet this requirement.
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height. All installation and
service may only be performed by authorized personnel. No unauthorized persons shall have access to the
service area.
NOTES:
Dimensions indicated ** are for ADA frontal approach installation. Adjust vertical dimension **
as required to comply with federal, state, and local codes. For Child ADA compliant parallel approach,
decrease spout height to 30” maximum above finished floor. Provide clear floor space as required.
A171.8
Page 2 of 13
Revised:
12/26/17
7020-904-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
GENERAL NOTES:
ALL DIMENSIONS ARE IN INCHES [MM]
ALLOW 4 INCHES [102 MM] MINIMUM CLEARANCE PER SIDE FOR VENTILATION
DIMENSIONS SHOWN ARE FOR ADA ADULT HEIGHT. ADJUST VERTICAL
DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES.
STOP VALVE, P-TRAP, & ELECTRICAL OUTLET NOT SUPPLIED.
IMPORTANT: COOLERS MUST BE ATTACHED TO WALL WITH APPROPRIATE
1.
2.
*3.
4.
5.
1
3
8
"
4
5
8
"
12"
TAIL
PIECE
*33"
ANCHOR SCREWS.
6
1
2
"
7
7
8
"
*22"
5
1
4
"
A. 3/8" NCT SUPPLY INLET
B. WASTE OUTLET FOR 1-1/4" P-TRAP BY OTHERS.
C. ELECTRICAL SERVICE ROUGH.
D. Ø3/8" HANGER BRACKET PUNCHING, 3 PLACES
FOR ANCHORING HARDWARE BY OTHERS.
E. Ø1/4" PUNCHING, 2 PLACES FOR ANCHORING
HARDWARE BY OTHERS.
A
B
C
E
D
19
3
8
"
7
1
4
"
*15
5
8
"
13
3
8
"
18
1
2
"
*16
3
8
"
2
1
4
"
4
1
4
"
6
5
8
"