ZXR10 T8000 Hardware Installation Guide (Cluster)
Table B-4 User Equipment Side Power Port ID Format
ID
Meaning
Specification
Example
X: System name
A: Equipment ID
X: PW
A: Power Cabinet ID
PW03
B: Power cable type (number
and letter)
Consistent with power cable types
PE/-48 V/-48 V RTN
C: Row/Line ID
Add “R” (ROW) at the end of Row ID;
add “L” (Line) at the end of Line ID
2R/2L
XA-B-C-D
D: Port ID
Power Interface ID
15
B.2.3.2 Label Example
The example is to number a -48 V power cable connecting from Port 1 located at Cabinet
IP01 to Port 15 located at Row 2 of Cabinet PW03 on user side. It is recommended to
arrange label content in the way as described in
Figure B-3
.
Figure B-3 Knife-Shaped Power Cable Label Example
B.2.4 Fiber Cable
B.2.4.1 Label Content
Mark the labels at two cable ends as follows.
l
One end: “FR:” used to indicate optical interface ID at local end.
l
The other end: “To:” used to indicate optical interface ID at opposite end.
ID format requirements of the fiber pigtail interfaces on the ZTE communication equipment
side are shown in
Table B-5
.
B-6
SJ-20110901170352-005|2011-10-15 (R2.0)
ZTE Proprietary and Confidential