  ELECTRICAL PRECAUTIONS-

 Before servicing a pump, always shut off the main power breaker and then unplug the pump 

- making sure you are wearing insulated protective sole shoes and not standing in water.  Under flooded conditions, contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.

 Submersible pumps contain oils which becomes pressurized and hot under operating conditions. 

Allow 2½ hours after disconnecting before 

attempting service.

If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump.  Service must be 

performed by Zoeller Authorized Service Stations.  Go to www.zoellerpumps.com/service stations to find the Authorized Service Station in your area.

SERVICE CHECKLIST

TROUBLESHOOTING INFORMATION

1.  Charging and charged LED’s alternate frequently.

 

(a)  This is normal.

2.  DC Pump won’t run.

 

(a)  Check 15 amp fuse in line from pump to switch (see fig. 4). If fuse 

is blown, replace with 15 amp Littelfuse type 3AG, series 311.

 

(b)  Check for proper connections.

 

(c)  Check all wire terminal points.  Clean if required.

 

(d)  Check for low battery.  Service battery if required.

3.  Pump runs but pumps very little or no water.

 

(a)  Check for low battery.  Battery will recharge if Red power “on” 

light indicates power has been restored and the float switch is 

in the off position.

 

(b)  If immediate usage is required, remove and replace dead 

battery with a full recharged battery.

 

(c)  Due to varying conditions the pump may continue to run on a 

low battery without sufficient power to remove water.  Pump will 

not stop running until battery is completely discharged.

 (d) 

CAUTION

 Weak batteries can be recharged but may 

not store sufficient energy for full service.  A weak recharged 

battery can only be detected by reduced pumping time or by 

checking each cell with a hydrometer.  If your emergency pump 

system is used frequently the battery should be checked by a 

qualified battery dealer.

4.  Pump cycles too frequently.

 

(a)  Check positions of rubber stops on float rod.

 

(b)  Adjust upper rubber float stop as required.  Recommended for 

standard installation.

5.  Float switch in “on” position. Pump won’t run.

 

(a)  Remove pump.  Check for obstruction in pump preventing 

impeller from rotating.

6.  Pump runs, but pumps water intermittently.

 

(a)  Pump is air locking.  Check flow of water incoming to sump. If 

water is entering the sump at a high velocity creating a turbulent 

condition, a mixture of air and water may cause a complete 

or partial air lock and reduce or stop the flow of water in the 

discharge pipe.

 

(b)  Baffle the incoming stream of water to reduce turbulence. 

Diverting water stream against wall of basin usually corrects an 

air lock problem.

7.  Water level stays high. DC Pump continues to run.

 

(a)  Battery is low.

 

(b)  If power has been restored and water in sump remains high 

check primary pump.  Service if required.

  

(c)  After several hours the battery will be restored to full charge.

8.  Alarm sounds during battery recharge cycle.

 

(a)  Push alarm reset (max. 3 times). If condition persists, replace 

battery.

 

(b)  To silence alarm if alarm will not reset, unplug the charger from 

115 V wall outlet, then disconnect the black lead from charger on 

negative (-) battery post.  Check battery. Replace if necessary.  

Reconnect and refer to Installation (step 7).

9.  Alarm does not sound when pump runs.

 

(a)  Pump needs to run for 1 or more seconds before alarm 

sounds.

 

(b)  Be sure alarm hasn't been silenced. Quickly press and release 

reset button.

 

(c)  Inspect the connection between the green wire and the blue 

connecter on the white wire. Verify that the metal spade has not 

"missed" its target.

CONDITION

COMMON CAUSES

A. Pump will not start or run.

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically, motor 

or wiring shorted. Float assembly held down. Switch, damaged or out of adjustment.

B. Motor overheats and trips 

overload or blows fuse.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, motor shorted.

C. Pump starts and stops too often. Float switch tether length too short, check valve stuck open, or none installed in long distance line, overload open, bidding, 

sump pit too small.

D. Pump will not shut off.

Debris under float assembly, float bound by basin sides or other, switch, damaged or out of adjustment.

E. Pump operates but delivers little 

or no water.

Check inlet, strainer housing, discharge pipe, and vent holes for obstructions.  Discharge head exceeds pump capacity. 

Low or incorrect voltage. Incoming water containing air or causing air to enter pumping chamber.  Incorrect motor rotation. 

(3 phase pumps only)

F. Drop in head and/or capacity 

after a period of use.

Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly deteriorate 

impeller and pump housing. Check line. Remove base and inspect.

G. If tank or fittings leak.

Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do not over tighten 

fittings or screws.

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Summary of Contents for ProPak 507

Page 1: ...dinances 6 FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING Single phase pumps are supplied with a 3 prong grounded plug to help protect you against the possibility of electrical shock DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN The 3 prong plug must be inserted into a mating 3 prong grounded receptacle If the installation does not have such a receptacle it...

Page 2: ...batteries We offer both a Water Acid Deep Cycle Battery and maintenance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 8 2 4 mm of static head Actual times will vary depending on static head volume of water entering the pit and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 m...

Page 3: ...TALLATION FOR ALL APPLICATIONS EASY DO S DON TS FOR INSTALLING A SUMP PUMP 1 DO read thoroughly all installation material provided with the system 2 DO inspect system for any visible damage caused by shipping Contact dealer if system appears to be damaged 3 DO clean all debris from the sump Be sure that the pump will have a hard flat surface beneath it DO NOT install on sand gravel or dirt 4 DO be...

Page 4: ...HTEN ONLY WEEP HOLE MUST BE VISIBLE FLOAT SWITCH DC PUMP M73 PRIMARY PUMP CLAMP TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM FIGURE 1 R R DC PUMP PLUMBED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE 1 25 MM MIN ABOVE CENTER OF TEE SEE INSTALLATION NOTE 3 VERIFY WEEP HOLE IS VISIBLE SEE PUMP INSTALLATION INSTRUCTIONS CHECK VALVE WEEP HOLE PROVIDED PUM...

Page 5: ...may be set on a nearby shelf or ledge The control charger should be located 3 0 9 m or 4 1 2 m above the sump 5 Connect the green sensor wire to the sensor connector figure 3 6 Connect the leads from the control charger to the battery terminals White positive lead to positive terminal and black negative lead INITIAL START UP AND OPERATION 1 Test the installation for leaks by running water into the...

Page 6: ...ECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locations SK2501 BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER FIG 5 DC BACK UP PUMP CLAMP FLOAT SWITCH WHITE LEAD TO POSITIVE BLACK LEAD TO DC PUMP ...

Page 7: ...condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulence Diverting water stream against wall of basin usually corrects an air lock problem 7 Water level stays high DC Pump continues to run a Battery is low b If power has been restored and water in sump remains ...

Page 8: ...CYCLED CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH BLACK LEAD WHITE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can be pressed to clear alarm buzzer light and or display Can be held f...

Page 9: ... la bombanecesiteconectarseaunacajadeconexiónestancaalagua sepuede quitar el enchufe y empalmarla al cable de alimentación debidamente puesto a tierra Para mayor seguridad es posible que este circuito esté protegido con un interruptor con detección de falla a tierra La instalación completa debe cumplir el Código Eléctrico Nacional y todos los códigos y disposiciones locales pertinentes 6 PARA SU P...

Page 10: ...cerá garantía alguna por ningún material o producto que haya sido desarmado sin aprobación previa del Fabricante o que haya sido sometido a uso indebido aplicación indebida negligencia alteración accidente o acto de naturaleza que no haya sido instalado usado o mantenido según las instrucciones de instalación del Fabricante que haya sido expuesto a sustancias foráneas que incluyen pero no se limit...

Page 11: ... el contenedor para agua debe quedar limpio y sin residuos 8 La válvula de paso o la válvula de bola deben ser suministradas por el instalador e instaladas de acuerdo con todos los códigos 9 Se requieren sellos estancos al gas que retengan los gases y olores 10 Ventile los gases y olores hacia la atmósfera a través de una tubería de ventilación 11 Instale el soporte de la bomba Zoeller modelo 10 2...

Page 12: ...EBE ESTAR VISIBLE INTERRUPTOR DE FLOTADOR BOMBA CC M73 BOMBA PRINCIPAL ABRAZADERA INSTALACIÓN NORMAL VISTA EN DESPIECE DEL SISTEMA DE LA BOMBA FIGURA 1 R R BOMBA DE CC CONECTADA EN LÍNEA CON BOMBA SUMERGIBLE CAJA DE BATERÍA IMPORTANTE EL NIVEL DE APAGADO DEL CONJUNTO DE FLOTADOR DEBE ESTAR A UN MIN DE 2 5 CM 1 PULG POR ENCIMA DEL CENTRO DE LA T VEA LA NOTA DE INSTALACIÓN 3 VERIFIQUE QUE EL ORIFICI...

Page 13: ... conveniente el cargador de control puede ajustarse en un estante o repisa que esté cerca El cargador de control debe estar situado a 0 9 o 1 2 m 3 o 4 pies por encima del sumidero 5 Conecte el cable verde del sensor al conector del sensor figura 3 6 Conecte los cables del cargador de control a los terminales de la batería El cable blanco pos al terminal positivo y el cable negro ARRANQUE INICIAL ...

Page 14: ... con todos los códigos eléctricos y de instalación sanitaria aplicables incluyendo pero sin limitarse al Código Eléctrico Nacional los códigos locales regionales y o los códigos estatales de instalación sanitaria etc No se debe usar las instalaciones en lugares peligrosos No está diseñada para uso en lugares peligrosos SK2501 CAJA DE BATERIA BATERÍA MARINA DE 12 V PROVISTA POR EL USUARIO FIG 5 BOM...

Page 15: ...orriente de 115 V y desconecte el cable negro negativo del cargador de la batería Compruebe la batería Reemplace el motor si es necesario Vuelva a conectar y consulte el paso Instalación paso 7 9 La alarma no suena cuando la bomba está en funcionamiento a La bomba tiene que estar en funcionamiento durante 1 o más segundos antes de que suene la alarma b Asegúrese de que alarma no haya sido silencia...

Page 16: ...BAJA ALARMA DESACTIVADA CONTACTOS DE LAALARMA CABLE VERDE AL INTERRUPTOR DE FLOTADOR CABLE NEGRO CABLE BLANCO FIGURA 4 SK2503 FIGURA 5 SK2958 PANTALLA LCD Y FUNCIONES DEL TECLADO Hay dos botones en la parte frontal del cargador El botón de desplazamiento se utiliza para desplazarse por la información en la pantalla LCD El botón de reinicio de la alarma Puede ser presionado para silenciar el timbre...

Page 17: ...A BROCHE DE MISE À TERRE La fiche à 3 broches doit être insérée dans une prise à 3 broches mise à la terre Si l installation ne comprend pas de prise il faut la changer pour le type approprié la câbler et la mettre à la terre en conformité avec le code national de l électricité ainsi que tous les codes et règlements locaux applicables 7 Risqued électrocution Nepasenleverlecordond alimentationniled...

Page 18: ...Il faut utiliser une batterie à décharge poussée B C I de taille 27 avec une réserve de 175 minutes ou de plus grande capacité IL NE FAUT PAS utiliser de batterie sans entretien sauf si elle est du type à électrolyte gélifié ou de type AGM Il faut remplacer la batterie tous les trois ans Il ne faut pas permettre l accumulation de corrosion sur les bornes de la batterie Il ne faut pas mettre la bat...

Page 19: ...nstaller and installed according to any and all codes 9 Gas tight seals required to contain gases and odors 10 Des joints étanches aux gaz sont nécessaires pour contenir les gaz et les odeurs 11 Installer le pied de pompe Zoeller modèle 10 2421 sous la pompe pour fournir une cuve de décantation INSTALLATION RECOMMANDÉE POUR TOUTES APPLICATIONS CONSEILS POUR L INSTALLATION D UNE POMPE DE PUISARD 1 ...

Page 20: ... ÉVENT DOIT ÊTRE VISIBLE INTERRUPTEUR À FLOTTEUR POMPE C C POMPE PRINCIPALE M73 COLLIER INSTALLATION TYPIQUE VUE EXPLOSÉE DE LA POMPE FIGURE 1 R R IMPORTANT LE NIVEAU D ARRÊT DU FLOTTEUR DOIT ÊTRE À 2 5 CM 1 PO AU MINIMUM AU DESSUS DU CENTRE DU TÉ VOIR LE POINT 3 DE L INSTALLATION S ASSURER QUE LE TROU D ÉVENT EST VISIBLE VOIR LES INDICATIONS D INSTALLATION DE LA POMPE CLAPET ANTIRETOUR TROU D ÉVA...

Page 21: ... 3 et 4 pi au dessus du puisard 5 Raccorder le fil vert du capteur au raccordement du capteur figure 3 6 Brancher les fils du chargeur aux bornes de la batterie Le fil positif blanc à la borne positive et le fil négatif noir à la borne négative de la batterie Lorsque la connexion est bonne une alarme de test retentit DÉMARRAGE INITIAL ET FONCTIONNEMENT 1 Tester l installation à la recherche de fui...

Page 22: ...allations doivent être conformes aux codes électriques et de plomberie applicables y compris mais pas limité aux codes électriques nationaux locaux régionaux et aux codes de plomberie provinciaux Pas conçu pour utilisation dans les endroits dangereux SK2501 FIGURE 3 Copyright 2016 Zoeller Co Tous droits réservés BOÎTIER DE LA BATTERIE 12 V BATTERIE MARINE FOURNIE PAR L UTILISATEUR POMPE DE SECOURS...

Page 23: ...e la prise murale 115 V puis débrancher le fil noir du chargeur sur la borne négative de la batterie Vérifier la batterie La remplacer si nécessaire Rebrancher et se référer à l installation étape 7 9 L alarme ne sonne pas lorsque la pompe fonctionne a La pompe doit fonctionner pendant au moins une seconde avant que l alarme ne sonne b S assurer que l alarme n est pas en mode silencieux Appuyer et...

Page 24: ...orsque le flotteur l est aussi L alarme est retardée afin de réduire les nuisances sonores Le voyant jaune alarme désactivée indique que l alarme est actuellement en mode silencieux DÉTECTEURS DE MONOXYDE DE CARBONE Que vous ayez une pompe de secours Basement Sentry ou d une marque concurrente toutes les batteries produisent des sous produits gazeux lorsqu elles sont en charge Certains de ces sous...