INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST

1.  Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs 

from the pump.

2.   Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.

SEE BELOW FOR 

LIST OF WARNINGS

  1.   To reduce the risk of electrical shock, a properly grounded receptacle or 

control box must be installed in accordance with the governing codes. 
Never remove ground pin from plug.

  2.   Make certain that the receptacle or control box is within the reach of the 

power supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that 

are too long or too light do not deliver sufficient voltage to the pump motor, 

and they could present a safety hazard if the insulation were to become 
damaged or the connection end were to fall into a damp or wet area.

  3.   Make sure the pump's electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity. A separate branch circuit is recommended, 
sized according to the governing electrical codes for the current shown 
on the pump name plate.

  4.   Testing for ground. As a safety measure, each electrical outlet should be 

checked for ground using a circuit analyzer which will indicate if the power, 
neutral, and ground wires are correctly connected to your outlet. If they 

are not, call a qualified, licensed electrician.

  5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS 

POWER SOURCE BEFORE HANDLING. If pump is wired direct, de- 
energize the circuit at the control box. DO NOT, UNDER ANY CIRCUMSTANCES, 
REMOVE THE GROUND PIN. Wear insulated protective shoes, and do not 
stand in water. Pumps equipped with a grounded plug are designed to help 
protect against electrical shock. A properly grounded receptacle or control 
box must be installed in accordance with governing codes.

  6.   Installation and servicing of the pump's electrical circuits and hardware 

should only be performed by a qualified, licensed electrician.

  7.   Installation and maintenance of this appliance is not intended for persons 

(including children) with reduced physical, sensory or mental capabilities, or 
lack of experience or knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a person responsible for 
their safety.

  8.   Risk of electrical shock. Do not remove power supply cord and strain relief 

or connect conduit directly to the pump. If the supply cable is damaged, it 
must be replaced by an authorized Zoeller representative.

  9.   Risk of electrical shock. These pumps have not been investigated for use 

in swimming pools and marine areas.

10. Use with approved motor control that matches motor input in full load amperes.

  1.   Check to be sure your power source is capable of handling the voltage 

requirements of the motor, as indicated on the pump name plate.

  2.  The installation of variable level float switches is the responsibility of the 

installing party, and care should be taken that the tethered float switch will 

not hang up on the pump apparatus or pit peculiarities and is secured so 

that the pump will shut off. It is recommended to use rigid pipe and fittings 

and the pit be 18" (45 cm) or larger in diameter. 

  3.  Vent hole. It is necessary that all submersible sump, effluent, and sewage 

pumps capable of handling various sizes of solid waste be of the bottom 

intake design to reduce clogging and seal failures. If a check valve is 

incorporated in the installation, a 3/16" (5 mm) vent hole must be drilled in 

the discharge pipe below the check valve and pit cover to purge the unit 

of trapped air. Vent hole should be checked periodically for clogging. The 

vent hole on a High Head application may cause too much turbulence. You 

may not want to drill one. If you choose not to drill a vent hole, be sure 

the pump case and impeller is covered with liquid before connecting the 

pipe to the check valve. NOTE: THE HOLE MUST BE BELOW THE BASIN 

COVER AND CLEANED PERIODICALLY. Water stream will be visible when 

pump is operating.

  4.   Pump should be checked frequently for debris and/or build up which may 

interfere with the float “on” or “off” position. Repair and service should 

be performed by an authorized Zoeller Company representative only.

  5.  Maximum operating temperature must not exceed 140 °F (60 °C).

  6.  Do not operate a pump in an application where the Total Dynamic Head is 

less than the minimum Total Dynamic Head listed on the Pump Performance 

Curves.

  7.  For health reasons, do not unplug, turn off, or disable pump and use pump 

tank system as a way to fill up a sink or laundry tray, etc.

  8.  This unit is not designed for salt water or brine applications. Use with salt 

water or brine will void warranty.

  9.   Pump may contain oil, which becomes pressurized and hot when operating. 

Allow 2-1/2 hours after disconnecting before attempting service.

10.   Pump is not intended for potable water due to possible contamination by 

oil contained in the pump.

11.   This pump has been evaluated for use with water only.

NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL 

standard UL778.  CSA certified pumps are certified to CSA standard C22.2 No. 108.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

P/N 083316

Certified to cCSAus 

Standard

C22.2 No. 108

c         us

Register your 

Zoeller Pump Company Product 

on our website:

http://reg.zoellerpumps.com/

DO NOT USE FOR PUMPING OILS, GASOLINE OR 

ANY PETROLEUM  

BY-PRODUCTS.

Summary of Contents for 5054

Page 1: ...ove power supply cord and strain relief or connect conduit directly to the pump If the supply cable is damaged it must be replaced by an authorized Zoeller representative 9 Risk of electrical shock These pumps have not been investigated for use in swimming pools and marine areas 10 Usewithapprovedmotorcontrolthatmatchesmotorinputinfullloadamperes 1 Check to be sure your power source is capable of ...

Page 2: ... Be sure that the pump will have a hard level surface beneath it DO NOT install on sand gravel or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DOalwaysconnecttoaseparatelyprotectedandproperlygrounded circuit DO NOT ever cut splice or damage power cord Only ...

Page 3: ...ivalent in diameter to the pump s discharge 7 Basin must be in accordance with governing codes and specifications 8 Pump must be level and float mechanism s clear of sides of basin before starting pump 9 Basin must be clean and free of debris after installation 10 Gate valve shut off valve or ball valve to be supplied by installer and installed according to any and all codes 11 Locate float switch...

Page 4: ...is connected IMPORTANT NOTICE Some insurance policies both commercial and residential extend coverage for damages incurred by product failure You will need to have possession of the product to support your claim in most cases Zoeller Pump Company will exchange the unit or refund the original purchase price once the claim is settled with the insurer in the case where you need to retain possession o...

Page 5: ...or Zoeller 9 Riesgo de descarga eléctrica No se ha investigado el uso de estas bombas en áreas marinas y en piscinas 10 Usar con el control del motor aprobado que corresponda a la entrada del motor en amperaje a plena carga 1 Asegúrese de que la fuente de energía eléctrica sea capaz de manejar los requisitos de voltaje del motor según se indica en la placa de identificación de la bomba 2 Lainstala...

Page 6: ...to de los interruptores de control de nivel 5 SIEMPRE desconecte la bomba de la fuente de alimentación eléctrica antes de manipularla SIEMPRE conecte la bomba a un circuito protegido separadamente y con puesta a tierra adecuado NO corte empalme o dañe el cable de alimentación eléctrica Empalme únicamente cuando hay una caja de conexión hermética NO transporte o levante la bomba por su cable de ali...

Page 7: ...escarga de tamaño completo 7 El contenedor para agua debe estar de acuerdo con los códigos y las especificaciones aplicables 8 La bomba debe estar nivelada y el mecanismo del flotador libre de los lados del contenador para agua antes de encender la bomba 9 El contenador para agua debe estar limpio y libre de escombros después de la instalación 10 El instalador deberá suministrar una válvula de pas...

Page 8: ...LIVIANO BRIDA COMÚN DE LA TUBERÍA RAMAL DE FLOTADORES 10 1457 CON TRES FLOTADORES INSTRUCCIONES PARA EL CABLEADO MONOFÁSICO ADVERTENCIA PARA SU PROTECCIÓN SIEMPRE DESCONECTE LA BOMBA DE LA FUENTE DE ALIMENTACIÓN ELÉCTRICA ANTES DE MANIPULARLA Las bombas monofásicas se suministran con enchufes de 3 patillas con puesta a tierra para ayudar a protegerle contra la posibilidad de descarga eléctrica NO ...

Page 9: ... pompe Silecâbled alimentationestendommagé unreprésentantautorisé par Zoeller doit le remplacer 9 Risque d électrocution L usage de ce type de pompe dans une piscine de natation et des zones marines n a pas été étudié 10 Utiliserundémarreurapprouvéconvenantaucourantàpleinechargedumoteur 1 Vérifierquelecircuitd alimentationaunecapacitésuffisantepouralimenter le moteur comme indiqué sur la pompe ou ...

Page 10: ... niveau 5 ILFAUTtoujoursdébrancherl alimentationdelapompeavantdelamanipuler IL FAUT toujours brancher la pompe sur un circuit séparé mis à la terre IL NE FAUT JAMAIS couper faire une épissure ou endommager un cordon d alimentation Pour faire une raccordement il faut utiliser un boîtier de raccordement étanche IL NE FAUT PAS utiliser le cordon d alimentation pour transporter ou soulever la pompe IL...

Page 11: ... Utiliser une canalisation d évacuation équivalente en diamétre à l évacuation de la pompe 7 La cuve doit être conforme aux codes et à la règlementation en vigeur 8 Avant la mise en service la pompe doit être de niveau et le mécanisme du flotteur ne doit pas toucher les bords du puits 9 Après l installation le puits doit être propre et ne doit pas contenir de débris 10 Le robinet vanne la vanne d ...

Page 12: ...GÉRÉES POUR L INSTALLATION DU FLOTTEUR SUPPORT TYPIQUE DE FLOTTEUR POUR COUVERCLE DE PUITS EN ACIER ARBRE À FLOTTEURS HABITUEL SUR PUISARDS EN BÉ TON OLE COLENES MONANTES DE FOSSE SEPTIQUE SK1218 SK1217 COUVERCLE D ACCÈS COLLET DE TUYAU STANDARD TUYAU EN ACIER INOXYDABLE LÉGER OU EN PVC GRAVILLON 10 1457 SUPPORT MONTRÉ AVEC 3 FLOTTES AVERTISSEMENT POURDESRAISONSDESÉCURITÉ ILFAUTTOUJOURSDÉBRANCHERL...

Reviews: