SINGLE PHASE WIRING INSTRUCTIONS

 

FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. 

 Single phase pumps are supplied 

with a 3-prong grounded plug to help protect you against the possibility of electrical shock. 

DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND 

PIN

.  The 3-prong plug must  be inserted into a mating 3-prong grounded receptacle. If the installation does not have such a receptacle, it must be changed 

to the proper type, wired and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances.

 

Risk of electrical shock

.  Do not remove power supply cord and strain relief or connect conduit directly to the pump.

 Installation and checking of electrical circuits and hardware should be performed by a qualified licensed electrician.

 Units supplied without a plug (single and three phase) and single phase nonautomatic units with a 20 amp plug must have a motor control 

and liquid level control provided at time of installation. The control device should have suitable voltage, ampere, frequency, grounding and horsepower rating 

for the pump to which it is connected.

IMPORTANT NOTICE:

 Some insurance policies, both commercial and residential, extend coverage for damages incurred by product failure. You will need to have 

possession of the product to support your claim in most cases. Zoeller Pump Company will exchange the unit or refund the original purchase price once the claim 

is settled with the insurer in the case where you need to retain possession of the product to support a damage claim you submit to your insurance company.

On some installations, it may be desirable to install an independent hanger for the level control switches to avoid possible hang-ups on the pumps, piping, valves, etc.

SUGGESTED METHODS OF FLOAT INSTALLATION

TYPICAL FLOAT HANGER ON CONCRETE PITS

OR SEPTIC TANK RISERS

TYPICAL FLOAT HANGER ON STEEL COVER PITS

ACCESS COVER

STANDARD PIPE

FLANGE

PVC OR LIGHT WEIGHT

STAINLESS STEEL PIPE

PEA GRAVEL

TYPICAL FLOAT HANGER ON CONCRETE PITS

OR SEPTIC TANK RISERS

10-1457 FLOAT TREE

WITH 3 FLOATS SHOWN

SK1217

SK1218

All installations must comply with all applicable 

electrical and plumbing codes, including,  but not 

limited to, National Electrical Code, local, regional, 

and/or state plumbing codes, etc. Not intended for 

use in hazardous locations.

TYPICAL EFFLUENT INSTALLATION

SK3118

SEPTIC TANK

WW FILTER

DOSING CHAMBER

OFF

TURN

U.F. TYPE WIRE

GROUND LINE

SOURCE

TO AC

ALARM FLOAT

TURN
ON

TO LOW PRESSURE SYSTEM,

MOUND SYSTEM, SAND FILTER,

LEACHING FIELD OR OTHER

ONSITE DISPOSAL SYSTEM. 

© Copyright 2021. All rights reserved.

These are the original instructions.

Summary of Contents for 5054

Page 1: ...ove power supply cord and strain relief or connect conduit directly to the pump If the supply cable is damaged it must be replaced by an authorized Zoeller representative 9 Risk of electrical shock These pumps have not been investigated for use in swimming pools and marine areas 10 Usewithapprovedmotorcontrolthatmatchesmotorinputinfullloadamperes 1 Check to be sure your power source is capable of ...

Page 2: ... Be sure that the pump will have a hard level surface beneath it DO NOT install on sand gravel or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DOalwaysconnecttoaseparatelyprotectedandproperlygrounded circuit DO NOT ever cut splice or damage power cord Only ...

Page 3: ...ivalent in diameter to the pump s discharge 7 Basin must be in accordance with governing codes and specifications 8 Pump must be level and float mechanism s clear of sides of basin before starting pump 9 Basin must be clean and free of debris after installation 10 Gate valve shut off valve or ball valve to be supplied by installer and installed according to any and all codes 11 Locate float switch...

Page 4: ...is connected IMPORTANT NOTICE Some insurance policies both commercial and residential extend coverage for damages incurred by product failure You will need to have possession of the product to support your claim in most cases Zoeller Pump Company will exchange the unit or refund the original purchase price once the claim is settled with the insurer in the case where you need to retain possession o...

Page 5: ...or Zoeller 9 Riesgo de descarga eléctrica No se ha investigado el uso de estas bombas en áreas marinas y en piscinas 10 Usar con el control del motor aprobado que corresponda a la entrada del motor en amperaje a plena carga 1 Asegúrese de que la fuente de energía eléctrica sea capaz de manejar los requisitos de voltaje del motor según se indica en la placa de identificación de la bomba 2 Lainstala...

Page 6: ...to de los interruptores de control de nivel 5 SIEMPRE desconecte la bomba de la fuente de alimentación eléctrica antes de manipularla SIEMPRE conecte la bomba a un circuito protegido separadamente y con puesta a tierra adecuado NO corte empalme o dañe el cable de alimentación eléctrica Empalme únicamente cuando hay una caja de conexión hermética NO transporte o levante la bomba por su cable de ali...

Page 7: ...escarga de tamaño completo 7 El contenedor para agua debe estar de acuerdo con los códigos y las especificaciones aplicables 8 La bomba debe estar nivelada y el mecanismo del flotador libre de los lados del contenador para agua antes de encender la bomba 9 El contenador para agua debe estar limpio y libre de escombros después de la instalación 10 El instalador deberá suministrar una válvula de pas...

Page 8: ...LIVIANO BRIDA COMÚN DE LA TUBERÍA RAMAL DE FLOTADORES 10 1457 CON TRES FLOTADORES INSTRUCCIONES PARA EL CABLEADO MONOFÁSICO ADVERTENCIA PARA SU PROTECCIÓN SIEMPRE DESCONECTE LA BOMBA DE LA FUENTE DE ALIMENTACIÓN ELÉCTRICA ANTES DE MANIPULARLA Las bombas monofásicas se suministran con enchufes de 3 patillas con puesta a tierra para ayudar a protegerle contra la posibilidad de descarga eléctrica NO ...

Page 9: ... pompe Silecâbled alimentationestendommagé unreprésentantautorisé par Zoeller doit le remplacer 9 Risque d électrocution L usage de ce type de pompe dans une piscine de natation et des zones marines n a pas été étudié 10 Utiliserundémarreurapprouvéconvenantaucourantàpleinechargedumoteur 1 Vérifierquelecircuitd alimentationaunecapacitésuffisantepouralimenter le moteur comme indiqué sur la pompe ou ...

Page 10: ... niveau 5 ILFAUTtoujoursdébrancherl alimentationdelapompeavantdelamanipuler IL FAUT toujours brancher la pompe sur un circuit séparé mis à la terre IL NE FAUT JAMAIS couper faire une épissure ou endommager un cordon d alimentation Pour faire une raccordement il faut utiliser un boîtier de raccordement étanche IL NE FAUT PAS utiliser le cordon d alimentation pour transporter ou soulever la pompe IL...

Page 11: ... Utiliser une canalisation d évacuation équivalente en diamétre à l évacuation de la pompe 7 La cuve doit être conforme aux codes et à la règlementation en vigeur 8 Avant la mise en service la pompe doit être de niveau et le mécanisme du flotteur ne doit pas toucher les bords du puits 9 Après l installation le puits doit être propre et ne doit pas contenir de débris 10 Le robinet vanne la vanne d ...

Page 12: ...GÉRÉES POUR L INSTALLATION DU FLOTTEUR SUPPORT TYPIQUE DE FLOTTEUR POUR COUVERCLE DE PUITS EN ACIER ARBRE À FLOTTEURS HABITUEL SUR PUISARDS EN BÉ TON OLE COLENES MONANTES DE FOSSE SEPTIQUE SK1218 SK1217 COUVERCLE D ACCÈS COLLET DE TUYAU STANDARD TUYAU EN ACIER INOXYDABLE LÉGER OU EN PVC GRAVILLON 10 1457 SUPPORT MONTRÉ AVEC 3 FLOTTES AVERTISSEMENT POURDESRAISONSDESÉCURITÉ ILFAUTTOUJOURSDÉBRANCHERL...

Reviews: