3
WIRING DIAGRAM
WHITE (1)
BLACK (2)
RED (3)
START
WINDINGS
MAIN WINDINGS
RUN CAP
GREEN
THERMAL PROTECTOR
Run Capacitor
50µF
400VAC
Two capacitors (25µF,400VAC)
in parallel.
RECOMMENDED INSTALLATION FOR ALL APPLICATIONS
PUMP PERFORMANCE CURVE
1. Electrical wiring and protection must be in accordance with governing
electrical codes.
2. Install proper combination union and check valve, preferably just above
the basin to allow easy removal of the pump for cleaning or repair.
If high head or below cover installation is required, use 30-0164 on
1-1/2" (DN40) pipe, 30-0152 on 2" (DN50) pipe and 30-0160 on 3" (DN80)
pipe.
3. All installations require a basin cover to prevent debris from falling into
the basin and to prevent injury.
4. When a check valve is installed, drill a 3/16" (5 mm) diameter hole in the
discharge pipe even with the top of the pump.
NOTE: THE HOLE MUST
ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY.
(High Head unit see “Caution” on front page). Water stream will be
visible from this hole when pump is operating.
5. Securely tape or clamp power cord to discharge pipe, clear of the float
mechanism(s).
6. Use a discharge pipe equivalent in diameter to the pump's discharge.
7. Basin must be in accordance with governing codes and
specifications.
8. Pump must be level and float mechanism(s) clear of sides of basin
before starting pump.
9. Basin must be clean and free of debris after installation.
10. Gate valve, shut-off valve, or ball valve to be supplied by installer and
installed according to any and all codes.
11. Locate float switches as shown in sketches. The best place for the “off”
point is above the motor housing and positioned 180° from the inlet.
Never put “off” point below discharge on pump.
12. Gas-tight seals are required to contain gases and odors.
13. Vent gases and odors to the atmosphere through vent pipe.
14. For proper spacing of "On" - "Off" switches refer to local or
national standards and guidelines.
15. Optional septic tank risers for easy access to pump, controls and filters.
WIRING DIAGRAM
Item #
HP
Voltage
Hz
Amp
5054-0004
1
230
60
14
MODEL 5054
Feet
Shut-off Head
Meters
Gal.
Liters
20
6.1
70
265
40
12.2
69
261
60
18.3
68
257
80
24.4
51
193
100
30.5
21
81
114 ft. (35 m)
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
PERFORMANCE CURVE
MODEL 5054
LITERS
GALLONS
10
20
30
50
60
70
80
40
40
80
120
160
200
240
280
FEET
METERS
10
0
20
30
40
50
60
70
80
90
100
110
120
36
30
24
18
12
6
FLOW PER MINUTE
TOT
AL
DYNAMIC HEAD
© Copyright 2021. All rights reserved.