2.2 I Installing the temperature sensor
(in depending to the model)
•
The water temperature sensor displays the water temperature value on the appliance screen and manages
chlorinati on according to the temperature. The sensor must measure the temperature of the water
upstream of any possible heati ng system.
•
The sensor is designed to be mounted on rigid 50 mm, 63 mm or 1 1/2’’ diameter PVC pipes. Do not install
on any other type of pipe.
•
Install the sensor either between the fi lter pump and the fi lter, or between the fi lter and any other
downstream equipment, voir
«2.1 I Installing the cell» :
-
Drill a hole in the pipe using a 9 mm (max. 10 mm) diameter drill bit, then deburr the hole,
- Install the
«O-ring» provided on the sensor body,
-
Secure the sensor using the stainless-steel clamping collar provided. Do not use excess strength.
: Sensor
: O-ring
: Stainless-steel clamping collar
2.3 I Installing the fl ow switch
(chlorinator only without pH Link or Dual Link modules)
In cases where a pH Link or Dual Link module is used, the fl ow switch will be installed on the POD
Kit,
see
“3.2 I Installing the fl ow switch on the POD kit”
•
The fl ow switch and its fi xture collar 50 mm diameter originally provided (diameter 63 mm available as a
spare part) must be installed just before the cell and aft er any valve
(
).
Use the threaded adapter and
Tefl on tape supplied to install the fl ow switch on its fi xture collar.
•
Screw down the fl ow switch using the clamping nut only (ti ghten by hand!)
(
).
Tightening nut
Water circulati on
directi on
By-pass installati on
In line installati on
• Failure to comply with these instructi ons could lead to the destructi on of the cell! The
manufacturer cannot be held liable in this case.
• The fl ow switch has a directi on for installati on (arrow indicated on it showing the fl ow
directi on for the water). Make sure that it is correctly placed on its fi xture collar so that it
stops the salt water chlorinator producti on when fi ltering is stopped.