44
7.2 I
Eff ects of the stabiliser on the chlorine and the ORP
A pool has a stabiliser content of 30 ppm and a pH of 7.4.
1 ppm free chlorine = 700 mV
Therefore, the user can set their chlorinati on requirement to 700 mV to maintain a level of 1 ppm in the pool.
If the level of stabiliser increases to 90 ppm, the ORP reading will be false.
1 ppm free chlorine = 500 mV
If the user keeps his setpoint at 700 mV, he will end up chlorinati ng up to 5 ppm !
CHL
ORINE RA
TE (PPM)
REDOX MEASUREMENT (MV)
Variati on of the Redox measurement based on
the stabiliser concentrati on (pH 7.4, 25°C)*
Setpoint
90 ppm stabiliser
30 ppm stabiliser
* Theoreti cal values to explain the principle. Actual values may vary
slightly depending on various pools waters
7.3 I "Help" menu
The chlorinator will automati cally noti fy you of any problems by displaying informati on messages. To help with the
understanding
of these messages, the device has a troubleshooti ng assistance menu which gives the meanings and the acti on to
take to solve the problem.
• Press
and browse the menu using the
butt ons. Press
to confi rm.
•
Select the error message using the
butt ons. Press
to confi rm.
•
The display will automati cally scroll through a certain number of suggested soluti ons to explain what to do. Once
automati c scrolling is complete, the chlorinator automati cally returns to the “Troubleshooti ng” menu.
• Press
to exit.
EN