35
5.3.4 Setti ng the ORP setpoint
Establishing the ORP setpoint determines when chlorine is produced by the appliance. Free chlorine level should be
checked every few days aft er initi al installati on.
Default ORP setti ng is 700 mV.
The setpoint value depends on the pool environment, its use, the rate of stabiliser present in the pool and so on.
• Press
and browse the menu using the
butt ons.
Press
to confi rm.
•
Select the desired setpoint value (from 600 mV to 900 mV is possible)
using the
butt ons.
• Press
to confi rm.
(ORP = Redox)
5.3.5 pH pump acti vati on
To avoid any exposure to acid during use, the dosing pump is deacti vated for the fi rst 8 hours the appliance operates.
During these fi rst 8 hours, the pH value measured and displayed is «- - - -».
• Hydrochloric acid is a hazardous chemical that may cause burns, lesions, and irritati ons.
Handle with extreme care using protecti ve equipment (gloves, goggles, coveralls). Refer to
the substance SDS sheet for more informati on.
• Always pour acid into water.
• Once cleaning is complete, dispose of the soluti on according to standard in eff ect in the
country of use.
•
The pH pump may be acti vated manually during this 8-hour period, press
and browse the menu
using the
butt ons.
Press
to confi rm.
• Press
to exit.