3.4.2 Installing the pH minus sucti on pipe
•
Cut a suitable length of pipe from the coil supplied to connect the container of pH minus to the peristalti c
pump.
•
Unscrew the connecti on cap
and
att ach the pipe to the connector on the inlet to the peristalti c pump,
see
illustrati on
.
Screw the connecti on cap.
•
Place the protecti on cover from the peristalti c pump.
•
Drill two holes in the cap on the pH minus container,
see illustrati on
:
-
One hole to match the diameter of the pipe used to suck the product up.
-
A second smaller hole to stop the container from deforming if a vacuum is created.
•
Pass the free end of the pipe through the hole drilled into the cap and put the ceramic counterweight and
threaded locking nozzle on the end,
see illustrati on
.
•
Ensure that ALL connecti ons are correct and waterti ght before operati ng the appliance.
Do not place the pH minus container directly under the electrical appliances in the technical premises to
prevent any risk of corrosion due to potenti al acid vapours.