background image

1

EN

 

 WARNINGS

•  Failure to respect the warnings may cause serious damage to the pool equipment or cause serious 

injury, even death.

•  The appliance is intended to be used only for swimming pools and spas; it must not be used for any 

purpose other than that for which it has been designed.

•  It is important that the appliance is operated by people who are competent and qualifi ed (both physically 

and mentally), aft er having read the instructi ons for use. All persons not meeti ng these criteria must 

not approach the appliance in order to avoid exposure to dangerous elements.

•  Keep the appliance out of the reach of children.

•  The appliance must be installed according to the manufacturer’s instructi ons and in compliance with 

local standards. The installer is responsible for installing the appliance and for compliance with nati onal 

installati on regulati ons. Under no circumstances may the manufacturer be held liable in the event of 

failure to comply with applicable local installati on standards.

•  Incorrect installati on and/or use may cause serious damage to property or serious injuries (possibly 

causing death). 

•  All  equipment,  even  postage  and  packing  paid,  travels  at  the  risks  and  perils  of  the  recipient.  The 

latt er shall issue reserves in writi ng on the carrier's delivery slip if damage is detected, caused during 

transport (confi rmati on to be sent to the carrier within 48 hours by registered lett er). In the event that 

an appliance containing coolant has been turned on its side, menti on your reservati ons in writi ng to 

the carrier.

•  If  the  appliance  suff ers  a  malfuncti on,  do  not  try  to  repair  it  yourself.  Instead  contact  a  qualifi ed 

technician.

•  Refer to the warranty conditi ons for details of the permitt ed water balance values for operati ng the 

appliance.

•  If any safety device is removed, bypassed, or shunted, the warranty will automati cally be void. This 

also applies if any parts are replaced with parts that are not acquired from an authorized Zodiac parts 

outlet.

•  Do not spray insecti cide or any other chemical (infl ammable or non-infl ammable) in the directi on of the 

appliance, as this may damage the body and cause a fi re.

•  The power supply to the appliance must be protected by a dedicated 30 mA residual current device, 

complying with the standards and regulati ons in force in the country in which it is installed.

•  Do not use an extension cord to plug in the appliance; plug it directly into a proper wall socket or outlet.

•  Before carrying out any operati ons, check that:

 

-

The voltage indicated on the appliance informati on plate corresponds to the mains voltage. 

 

-

The power grid is adapted to the power requirements of the appliance, and is properly grounded. 

 

-

The plug (where applicable) is suitable for the socket.

•  In the event of abnormal operati on or the release of odours from the appliance, turn it off  immediately, 

unplug it from its power supply and contact a professional.

•  Before any access to the appliance for any required service or maintenance, ensure that it is switched 

off  and disconnected from the power supply.

•  Do not disconnect and reconnect the appliance to the power supply when in operati on.

•  Do not pull on the power cord to disconnect it from the power supply.

•  Do not att empt to carry out any servicing or maintenance operati ons with wet hands or while the 

appliance is wet.

•  Clean the terminal board or the power supply socket before connecti on.

•  For any component or sub-assembly containing a batt ery: do not recharge or dismantle the batt ery, or 

throw it into a fi re. Do not expose it to high temperatures or direct sunlight.

•  In stormy weather, unplug the appliance to prevent it from suff ering lightning damage.

•  Do not immerse the appliance in water (with the excepti on of cleaners) or mud.

•  This  pump  is  compati ble  with  all  types  of  water  treatment  used  in  a  swimming  pool.  Refer  to  the 

Zodiac® warranty conditi ons for details of the permitt ed water balance values.

•  Never run the pump dry or out of the water (this will invalidate the warranty)

Recycling

This symbol means that your appliance must not be thrown into a normal bin. It will be selecti vely 

collected for the purpose of reuse, recycling or transformati on. If it contains any substances that may be 

harmful to the environment, these will be eliminated or neutralised.

Contact your retailer for recycling informati on.

Summary of Contents for FloPro VS

Page 1: ...0589800 B 2017 03 More documents on www zodiac poolcare com FloPro VS FR Instructions for installation and use English Filtration pump Translation of the original instructions in french EN PT ES DE NL...

Page 2: ......

Page 3: ...he direction of the appliance as this may damage the body and cause a re The power supply to the appliance must be protected by a dedicated 30 mA residual current device complying with the standards a...

Page 4: ...ervicing 19 Troubleshooting 20 5 1 I Appliance behaviour 20 Before handling the appliance it is essential that you read this installation and user manual as well as the warnings and warranty booklet d...

Page 5: ...3 EN Speci cations 1 1 I Description or A FloPro VS JEP with user interface AUT without user interface B 63 50 mm connectors x2 C Pump bases x2 D Cable gland x2 E Remote user interface kit...

Page 6: ...Maximum pump ow m h 30 7 Pump ow rate at 8 metres of head m h 26 0 Maximum pump head mH O 21 5 bar 2 1 Pump operation from 600 to 3 450 rpm Settings in intervals of 10 rpm Number of programmable speed...

Page 7: ...5 EN 1 4 I Performance curves Flow rate Manometric head...

Page 8: ...nd motor to cool The pump must not be installed in an area subjected to splashing rain or exposed to direct sunlight more than 3 m above the water level near a heat source or source of ammable gas in...

Page 9: ...installed above the water level Fit suction and discharge isolation valves if the pump is installed below the water level To help prevent di culty in priming install the suction pipe without high poi...

Page 10: ...l only start when commanded to do so via its user interface or via an external controller for example AquaLink TRi or iQPUMP The appliance s electrical supply must be provided through a protection and...

Page 11: ...low 4 green Do not cut the RS485 cable as this will prevent the user interface from being reconnected to the pump and will make it impossible to restore the factory settings The cable is xed to the pu...

Page 12: ...ble as this will prevent the user interface from being reconnected to the pump and will make it impossible to restore the factory settings The cable is xed to the pump and cannot be removed or extende...

Page 13: ...the correct length of cable for the extension and connect it to the RS485 terminal board then connect it inside the electrical compartment Fit the cover and the foam gasket in the position of the use...

Page 14: ...the grommet on the base see procedure 2 4 2 Remote user interface In the case of connection to an AquaLink TRi external controller this function will be automatically proposed by the controller 2 5 I...

Page 15: ...xed to the pump and cannot be removed or extended Never lay these low voltage cables in the same pipe as high voltage cables Theuserinterface wherepresent becomesinactiveifthepumpisconnectedtotheAquaL...

Page 16: ...of the active speed Pump speed Pump on Symbol Description Menu access button Con rm a selection Pre set eStar speed button 1 750 rpm Sub menu back button Pre set speed buttons Rotational speed modi ca...

Page 17: ...it is perfectly sealed Bleed any air present in the ltration circuit using the bleed normally present on the lter refer to the swimming pool lter s manual Check that there are no leaks on the hydrauli...

Page 18: ...access the Timer programme the speed that you want to programme must be running eStar speed or speed No 2 Speed LED Clock display Timer active Pump on red yes Timer active Pump o green yes Timer inac...

Page 19: ...e user interface has been idle for 2 minutes Light o screen not back lit Light on screen permanently back lit To choose the interface language English Spanish French German Italian or Dutch To choose...

Page 20: ...50 rpm Then the priming cycle time from 1 to 5 minutes The user interface displays when the pump is in the priming cycle To set the pre de ned eStar speed known by default as 1 Filtration The pump mea...

Page 21: ...he electrical power cable then unscrew the hydraulic connectors to store the pump in a dry place protected from frost Store the pump in a dry environment at a temperature that varies as little as poss...

Page 22: ...s The turbine and the pump di user are blocked or worn replace The di user seal is worn replace Reverse motor rotation three phase models only Check the electrical connection at the pump terminals Low...

Page 23: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: