manualshive.com logo in svg
background image

 

 

 

 

 

Variable Speed Pool Pump with Bluetooth

 

Installation and Operating Instructions 

Model: SP200BTP 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARNING: Failure to follow these instructions and comply with all 

applicable codes may cause serious bodily injury and/or property damage.

 

 

This pump requires professional expertise for installation and 

maintenance. The installation of this product should be carried out by a 

person knowledgeable in swimming pool plumbing requirements and 

who follows the installation instructions provided in this manual.

 

   Please pass these instructions on to the operator of this equipment. 

 

Содержание SILENSOR PRO SP200BTP

Страница 1: ...ause serious bodily injury and or property damage This pump requires professional expertise for installation and maintenance The installation of this product should be carried out by a person knowledg...

Страница 2: ...ey should not be used for any other purpose without first consulting your Davey Dealer or the Davey Customer Service Centre Every Davey SilensorPro is thoroughly water tested against a number of flow...

Страница 3: ...are used to This is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a sig...

Страница 4: ...The unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basi...

Страница 5: ...r Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the pool wate...

Страница 6: ...cated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation Technical Specifications Model SP200BTP He...

Страница 7: ...pump should be located as close to the water as practicable and mounted on a firm base in a well drained position high enough to prevent any flooding It is the installer s owner s responsibility to lo...

Страница 8: ...s on this product are constructed of ABS Some PVC jointing compounds are incompatible with ABS Check compound suitability before use Warning Ensure that an electrical isolation switch is located with...

Страница 9: ...pumps speed dial The use of any pipe smaller than those specified above is not recommended Suction piping should be free from all air leaks and any humps and hollows which cause suction difficulties...

Страница 10: ...c The pump enclosure has adequate drainage in the event of leakage c Any transport plugs are removed c The pipe work is correctly sealed and supported c The pump is filled with water to the inlet c Th...

Страница 11: ...st speed and therefore the greatest energy efficiency and savings See table below for all other dial positionspeeds and functions Operation Recommended Speed Setting Pool Filtration Speed 1 to 4 Sucti...

Страница 12: ...12 SP200BTP Performance...

Страница 13: ...cooled design for smooth and super quiet operation The pump has a water cooled membrane and jacket around the motor which helps to keep the pump cool during operation Waste heat off the motor is trans...

Страница 14: ...s or m3 hr Pairing a device to the pump 1 Open app 2 Turn dial on the pump from off to Bluetooth you will see the LED flash white for a second 3 Press the scan button 4 When setting up for the first t...

Страница 15: ...ne is not in range Anytime the dial is switched to the Bluetooth position it will run at the previous set speed after the priming cycle Schedule Mode Schedule mode allows you to set the pump speed by...

Страница 16: ...device and the pump can take up to 20 secondsdepending on the schedule selected Note The row at the bottom of the screen indicates a summary of where the schedule is by day and by hour This summary s...

Страница 17: ...External Timer Present Swipe this on or off depending on whether you are using an external timer chlorinator Disconnect Function The disconnect from pump function can be used to 1 Allow another device...

Страница 18: ...lug for 1 minute and plug back in to reset if problem persists contact your nearest dealer Pump Fault EEPROM Checksum Unplug for 1 minute and plug back in to reset if problem persists contact your nea...

Страница 19: ...er Speed 3 to 7 should be ample for most cleaners however if the cleaner requires better performance select speeds 7 to 10 4 The cleaner should only be connected for as long as is required to clean th...

Страница 20: ...he following condition may apply 1 The filter requires backwashing or it is blocked Refer to the relevant section in the Filter Manual 2 The pump is not primed Re prime as per instruction in Starting...

Страница 21: ...the power source NOTE If the pump is wired into a time clock or another automatic control the wiring should be removed by a qualified technician 2 Close the water valves on the pool return and the pu...

Страница 22: ...NOTES...

Страница 23: ...NOTES...

Страница 24: ...ulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061...

Отзывы: